| Literature DB >> 16459690 |
Maryam Al Nakib1, Grégory Garcia, Cyrille Bastide, Laurent Tomatis, Evelyne Ragni, Dominique Rossi.
Abstract
Suburethral TVT tape has become immensely popular since its invention in 1995. A new transobturator surgical approach was proposed in 2001, resulting in a modification of the quality of the tape available from various suppliers. The authors present 2 cases of obturator foramen abscess related to suburethral Uratape, occurring a long time after the procedure and requiring complete removal of the tape. These infections can be prevented by using good quality tape, which must be made from monofilament large-mesh woven polypropylene. The tape must be completely removed as early as possible in the case of vaginal erosion, even asymptomatic, via a transobturator approach, if necessary.Entities:
Mesh:
Year: 2005 PMID: 16459690
Source DB: PubMed Journal: Prog Urol ISSN: 1166-7087 Impact factor: 0.915