Literature DB >> 16456514

[Evaluation of setup error and adequate setup margins in patients with prostate cancer treated by IMRT and fixed in the prone position using a set of immobilization devices].

Toru Takakura1, Manabu Nakata, Shinsuke Yano, Takashi Okada, Takahiro Fujimoto, Kana Matsubara, Takashi Mizowaki, Kenji Takayama, Yoshinori Norihisa.   

Abstract

PURPOSE: Positional reproducibility in patients with prostate cancer fixed in the prone position with a set of immobilization devices for external-beam intensity-modulated radiation therapy (IMRT) was evaluated. In addition, the adequacy of our positional error reduction strategy and current planning target volume (PTV) margins was also evaluated.
RESULTS: Systematic error was corrected by the positional correction that we executed at the first stage of irradiation. The setup margin that we had calculated was 1.1 mm in the L-R direction, 1.3 mm in the A-P direction, and 2.7 mm in the C-C direction.
CONCLUSION: We determined that the effectiveness of the method of correcting the error margin and the setup accuracy of the fixed method were well maintained.

Entities:  

Mesh:

Year:  2006        PMID: 16456514     DOI: 10.6009/jjrt.62.130

Source DB:  PubMed          Journal:  Nihon Hoshasen Gijutsu Gakkai Zasshi        ISSN: 0369-4305


  2 in total

1.  Patient setup verification procedure for a portal image in a computed radiography system with a high-resolution liquid-crystal display monitor.

Authors:  Hideki Fujita; Michihiro Yamaguchi; Yuichi Bessho; Tomio Fujioka; Haruyuki Fukuda; Kenya Murase
Journal:  Radiol Phys Technol       Date:  2009-11-20

2.  Compare of Interfractional Setup Reproducibility Between Vacuum-Lock Bag and Thermoplastic Mask in Radiotherapy for Breast Cancer.

Authors:  Yaqi Song; Jin Peng; Qianfeng Chen; Honglei Luo
Journal:  Technol Cancer Res Treat       Date:  2021 Jan-Dec