Literature DB >> 16450901

Diagnostic utility of GLUT-1 expression in the cytologic evaluation of serous fluids.

Alaa Afify1, Heidi Zhou, Lydia Howell, Augusto F G Paulino.   

Abstract

OBJECTIVE: To evaluate the extent to which adenocarcinomas in body cavity fluids express GLUT-1 in comparison to currently available markers for adenocarcinomas. STUDY
DESIGN: Archival paraffin-embedded cell blocks of serous fluids from 25 cases of benign effusions containing reactive mesothelial cells and 39 cases of malignant effusions with metastatic adenocarcinoma (11 ovarian, 11 pulmonary, 9 gastrointestinal and 8 breast) were retrieved from the surgical pathology files. All cases were stained with antibodies for GLUT-1, Ber-Ep4, B72.3 and CEA. Positive staining was defined as distinct linear membrane staining for GLUT-1 and Ber-EP4, cytoplasmic staining for CEA, and cytoplasmic or membrane staining for B72.3. Strong staining in at least 10% of the tumor cells was required in order to consider the case positive for the particular marker.
RESULTS: GLUT-1 was expressed in 72% (28 of 39) of cases of malignant effusions: 100% (11 of 11) from the ovary, 91% (10 of 11) from the lung, 67% (6 of 9) from the gastrointestinal tract and 12% (1 of 8) from the breast. None (0 of 25) of the benign effusions expressed GLUT-1. Malignant effusions expressed CEA in 74% (29 of 39), Ber-Ep4 in 85% (33 of 39), and B72.3 in 62% (24 of 39). Benign effusions expressed CEA in 3 cases and B72.3 in 2 cases.
CONCLUSION: GLUT-1 is a useful marker that can be applied to cytologic specimens. It can be used as a reliable component of an antibody panel to distinguish reactive mesothelial cells from metastatic adenocarcinoma in particular adenocarcinomas of body cavity effusions, in particular adenocarcinomas of ovarian and pulmonary origin.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16450901     DOI: 10.1159/000326249

Source DB:  PubMed          Journal:  Acta Cytol        ISSN: 0001-5547            Impact factor:   2.319


  2 in total

Review 1.  Lung cancer cytology: potential pitfalls and mimics - a review.

Authors:  Michael O Idowu; Celeste N Powers
Journal:  Int J Clin Exp Pathol       Date:  2010-03-25

2.  Diagnostic accuracy of Ber-EP4 for metastatic adenocarcinoma in serous effusions: a meta-analysis.

Authors:  Bo Wang; Diandian Li; Xuemei Ou; Qun Yi; Yulin Feng
Journal:  PLoS One       Date:  2014-09-17       Impact factor: 3.240

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.