Literature DB >> 16450367

Quantitative myocardial infarction on delayed enhancement MRI. Part I: Animal validation of an automated feature analysis and combined thresholding infarct sizing algorithm.

Li-Yueh Hsu1, Alex Natanzon, Peter Kellman, Glenn A Hirsch, Anthony H Aletras, Andrew E Arai.   

Abstract

PURPOSE: To develop a computer algorithm to measure myocardial infarct size in gadolinium-enhanced magnetic resonance (MR) imaging and to validate this method using a canine histopathological reference.
MATERIALS AND METHODS: Delayed enhancement MR was performed in 11 dogs with myocardial infarction (MI) determined by triphenyltetrazolium chloride (TTC). Infarct size on in vivo and ex vivo images was measured by a computer algorithm based on automated feature analysis and combined thresholding (FACT). For comparison, infarct size by human manual contouring and simple intensity thresholding (based on two standard deviation [2SD] and full width at half maximum [FWHM]) were studied.
RESULTS: Both in vivo and ex vivo MR infarct size measured by the FACT algorithm correlated well with TTC (R = 0.95-0.97) and showed no significant bias on Bland Altman analysis (P = not significant). Despite similar correlations (R = 0.91-0.97), human manual contouring overestimated in vivo MR infarct size by 5.4% of the left ventricular (LV) area (equivalent to 55.1% of the MI area) vs. TTC (P < 0.001). Infarct size measured by simple intensity thresholdings was less accurate than the proposed algorithm (P < 0.001 and P = 0.007).
CONCLUSION: The FACT algorithm accurately measured MI size on delayed enhancement MR imaging in vivo and ex vivo. The FACT algorithm was also more accurate than human manual contouring and simple intensity thresholding approaches. (c) 2006 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16450367     DOI: 10.1002/jmri.20496

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  50 in total

1.  Reliability of myocardial salvage assessment by cardiac magnetic resonance imaging in acute reperfused myocardial infarction.

Authors:  Steffen Desch; Hubertus Engelhardt; Josefine Meissner; Ingo Eitel; Mahdi Sareban; Georg Fuernau; Suzanne de Waha; Matthias Grothoff; Matthias Gutberlet; Gerhard Schuler; Holger Thiele
Journal:  Int J Cardiovasc Imaging       Date:  2011-01-30       Impact factor: 2.357

2.  Quantitative assessment of myocardial fibrosis in an age-related rat model by ex vivo late gadolinium enhancement magnetic resonance imaging with histopathological correlation.

Authors:  Pascale Beliveau; Farida Cheriet; Stasia A Anderson; Joni L Taylor; Andrew E Arai; Li-Yueh Hsu
Journal:  Comput Biol Med       Date:  2015-08-08       Impact factor: 4.589

3.  Automated scar quantification by CMR: a step in the right direction.

Authors:  Steven K White; Andrew S Flett; James C Moon
Journal:  J Thorac Dis       Date:  2013-08       Impact factor: 2.895

4.  Quantitation of infarct size in patients with chronic coronary artery disease using rest-redistribution Tl-201 myocardial perfusion SPECT: correlation with contrast-enhanced cardiac magnetic resonance.

Authors:  David S Fieno; Louise E J Thomson; Piotr Slomka; Aiden Abidov; John D Friedman; Guido Germano; Daniel S Berman
Journal:  J Nucl Cardiol       Date:  2007-01       Impact factor: 5.952

5.  Controversies in cardiovascular MR imaging: reasons why imaging myocardial T2 has clinical and pathophysiologic value in acute myocardial infarction.

Authors:  Andrew E Arai; Steve Leung; Peter Kellman
Journal:  Radiology       Date:  2012-10       Impact factor: 11.105

6.  Early Gadolinium Enhancement for Determination of Area at Risk: A Preclinical Validation Study.

Authors:  Sophia Hammer-Hansen; Steve W Leung; Li-Yueh Hsu; Joel R Wilson; Joni Taylor; Anders M Greve; Jens Jakob Thune; Lars Køber; Peter Kellman; Andrew E Arai
Journal:  JACC Cardiovasc Imaging       Date:  2016-09-21

Review 7.  Cardiac imaging techniques for physicians: late enhancement.

Authors:  Peter Kellman; Andrew E Arai
Journal:  J Magn Reson Imaging       Date:  2012-09       Impact factor: 4.813

8.  How to quantify infarct size on delayed-enhancement MR images: a comparison between visual and quantitative approach.

Authors:  G Ligabue; F Fiocchi; S Ferraresi; A Barbieri; R Romagnoli; P Torricelli
Journal:  Radiol Med       Date:  2007-10-21       Impact factor: 3.469

Review 9.  Quantification in cardiac MRI: advances in image acquisition and processing.

Authors:  Anil K Attili; Andreas Schuster; Eike Nagel; Johan H C Reiber; Rob J van der Geest
Journal:  Int J Cardiovasc Imaging       Date:  2010-02       Impact factor: 2.357

10.  Quantification of late gadolinium enhanced CMR in viability assessment in chronic ischemic heart disease: a comparison to functional outcome.

Authors:  Aernout M Beek; Olga Bondarenko; Farshid Afsharzada; Albert C van Rossum
Journal:  J Cardiovasc Magn Reson       Date:  2009-03-09       Impact factor: 5.364

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.