Literature DB >> 16447094

MDCT angiography of living laparoscopic renal donors.

S Kawamoto1, E K Fishman.   

Abstract

Laparoscopic donor nephrectomy has become the accepted method of harvesting the kidney at many institutions because of multiple advantages over open donor nephrectomy. Spiral computed tomographic (CT) angiography provides accurate information of renal vascular anatomy and has become an accepted method of preoperative evaluation of potential laparoscopic renal donors. More recently, multidetector CT (MDCT) provides more detailed datasets compared with single-detector spiral CT and has been used for preoperative evaluation of laparoscopic donor nephrectomy to provide accurate anatomic information. MDCT (especially 16- and 64-slice MDCT) angiography has advantages over single-detector helical CT due to rapid scan time that allows coverage of a large volume of interest with higher spatial and temporal resolutions. In this article, we review the current status of MDCT angiography in the evaluation of laparoscopic renal donors and potential advantages of using this technology.

Entities:  

Mesh:

Year:  2006        PMID: 16447094     DOI: 10.1007/s00261-005-0371-z

Source DB:  PubMed          Journal:  Abdom Imaging        ISSN: 0942-8925


  5 in total

1.  [Analysis of 64-row multidetector CT images for preoperative angiographic evaluation of potential living kidney donors].

Authors:  D Blondin; K Andersen; P Kroepil; M Cohnen; U Mödder; W Sandmann; K Ivens; G Jung
Journal:  Radiologe       Date:  2008-07       Impact factor: 0.635

2.  Diagnostic accuracy of a volume-rendered computed tomography movie and other computed tomography-based imaging methods in assessment of renal vascular anatomy for laparoscopic donor nephrectomy.

Authors:  Shingo Yamamoto; Masao Tanooka; Kumiko Ando; Toshiko Yamano; Reiichi Ishikura; Michio Nojima; Shozo Hirota; Hiroki Shima
Journal:  Int Urol Nephrol       Date:  2009-03-06       Impact factor: 2.370

3.  Multidetector computed tomographic angiography evaluation of micropig major systemic vessels for xenotransplantation.

Authors:  Jung Min Ryu; Woong Yoon; Jae Hong Park; Seung Pil Yun; Min Woo Jang; Ho Jae Han
Journal:  J Vet Sci       Date:  2011-09       Impact factor: 1.672

4.  MDCT evaluation of potential living renal donor, prior to laparoscopic donor nephrectomy: What the transplant surgeon wants to know?

Authors:  Nitin P Ghonge; Satyabrat Gadanayak; Vijaya Rajakumari
Journal:  Indian J Radiol Imaging       Date:  2014-10

5.  Assessment of Potential Live Kidney Donors and Computed Tomographic Renal Angiograms at Christchurch Hospital.

Authors:  Thamer Alsulaiman; Stephen Mark; Sarah Armstrong; David McGregor
Journal:  Adv Urol       Date:  2016-03-10
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.