BACKGROUND: Although distal embolic protection (DEP) is increasingly utilized in saphenous vein graft percutaneous coronary intervention (SVG PCI), the clinical and economic outcomes of different DEP strategies are unknown.
METHODS: We compared 3 DEP strategies (no DEP, routine DEP, selective DEP in high-risk cases) in 126 consecutive cases of SVG PCI performed without DEP in a single catheterization laboratory over a 4-year period. No SVG PCI was excluded. High risk was defined using 2 multivariate predictors of embolic complication previously validated by NCDR (graft age greater than or equal to 8 years and or friable appearance with thrombus). Costs were determined by a ratio of cost-to-charges methodology and average cost of the two FDA-approved DEP devices ($1,350) with similar efficacy.
RESULTS: Without DEP, the incidence of embolic complications was 17% (22/126), resulting in major adverse coronary events (MACE) in 3.2% (4/126) of all cases: 2 deaths, 1 myocardial infarction, and 1 emergency coronary artery bypass. Embolic complications significantly increased both procedure costs by $2,725 (p < .001) and total hospital costs approximately $2,800 (p < 0.05). Risk adjustment for selective DEP use correctly predicted 86% (19/22) of embolic complications, including all MACE, at an incremental cost of $684 per patient for selective DEP versus $1,150 per patient for routine DEP. Selective DEP would cost $43,127 per death prevented versus $72,461 using routine DEP during the index hospitalization.
CONCLUSIONS: Embolic complications increase cost in excess of the cost of a DEP device. This risk adjustment model correctly predicted the majority of cases of embolic complication and all MACE, suggesting that selective DEP use may help reduce utilization of DEP by an almost 50% cost reduction compared to routine use.

Entities:  

Mesh:

Year:  2006        PMID: 16446515

Source DB:  PubMed          Journal:  J Invasive Cardiol        ISSN: 1042-3931            Impact factor:   2.022


  2 in total

1.  The role of distal myocardial protection devices during percutaneous coronary interventions.

Authors:  Diana A Gorog
Journal:  Curr Treat Options Cardiovasc Med       Date:  2007-02

2.  The economic burden of complications during percutaneous coronary intervention.

Authors:  Kurt M Jacobson; Kirsten Hall Long; Erin K McMurtry; James M Naessens; Charanjit S Rihal
Journal:  Qual Saf Health Care       Date:  2007-04
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.