Literature DB >> 16445262

Tracking of left ventricular long axis from real-time three-dimensional echocardiography using optical flow techniques.

F Veronesi1, C Corsi, E G Caiani, A Sarti, C Lamberti.   

Abstract

Two-dimensional echocardiography (2DE) is routinely used in clinical practice to measure left ventricular (LV) mass, dimensions, and function. The reliability of these measurements is highly dependent on the ability to obtain nonforeshortened long axis (LA) images of the left ventricle from transthoracic apical acoustic windows. Real time three-dimensional echocardiography (RT3DE) is a novel imaging technique that allows the acquisition of dynamic pyramidal data structures encompassing the entire ventricle and could potentially overcome the effects of LA foreshortening. Accordingly, the aim of this paper was to develop a nearly automated method based on optical flow techniques for the measurement of the left ventricular (LV) LA throughout the cardiac cycle from RT3DE data. The LV LA measurements obtained with the automated technique has been compared with LA measurements derived from manual selection of the LA from a volumetric display of RT3DE data. High correlation (r = .99, SEE = 1.8%, y = .94x + 5.3), no significant bias (-0.18 mm), and narrow limits of agreement (SD: 1.91 mm) were found. The comparison between the LA length derived from 2DE and RT3DE data showed significant underestimation of the 2DE based measurements. In conclusion, this study proves that RT3DE data overcome the effects of foreshortening and indicates that the method we propose allows fast and accurate quantification of LA length throughout the cardiac cycle.

Entities:  

Mesh:

Year:  2006        PMID: 16445262     DOI: 10.1109/titb.2005.855535

Source DB:  PubMed          Journal:  IEEE Trans Inf Technol Biomed        ISSN: 1089-7771


  10 in total

1.  3D dynamic position assessment of the coronary sinus lead in cardiac resynchronization therapy.

Authors:  Cristiana Corsi; Corrado Tomasi; Dario Turco; Massimo Margheri; Claudio Lamberti; Stefano Severi
Journal:  Med Biol Eng Comput       Date:  2011-06-29       Impact factor: 2.602

2.  Evaluation of advanced Lukas-Kanade optical flow on thoracic 4D-CT.

Authors:  Christoph Bernhard Hoog Antink; Tarunraj Singh; Puneet Singla; Matthew Podgorsak
Journal:  J Clin Monit Comput       Date:  2013-04-03       Impact factor: 2.502

3.  Three-Dimensional Mitral Valve Morphology in Children and Young Adults With Marfan Syndrome.

Authors:  Matthew A Jolley; Peter E Hammer; Sunil J Ghelani; Adi Adar; Lynn A Sleeper; Ronald V Lacro; Gerald R Marx; Meena Nathan; David M Harrild
Journal:  J Am Soc Echocardiogr       Date:  2018-08-08       Impact factor: 5.251

4.  Dynamic 3-dimensional echocardiographic assessment of mitral annular geometry in patients with functional mitral regurgitation.

Authors:  Kamal R Khabbaz; Feroze Mahmood; Omair Shakil; Haider J Warraich; Joseph H Gorman; Robert C Gorman; Robina Matyal; Peter Panzica; Philip E Hess
Journal:  Ann Thorac Surg       Date:  2012-10-25       Impact factor: 4.330

5.  Region-based endocardium tracking on real-time three-dimensional ultrasound.

Authors:  Qi Duan; Elsa D Angelini; Susan L Herz; Christopher M Ingrassia; Kevin D Costa; Jeffrey W Holmes; Shunichi Homma; Andrew F Laine
Journal:  Ultrasound Med Biol       Date:  2008-10-29       Impact factor: 2.998

6.  The Value of Elastic Modulus Index as a Novel Surrogate Marker for Cardiovascular Risk Stratification by Dimensional Speckle-Tracking Carotid Ultrasonography.

Authors:  Ji Hyun Yoon; In-Jeong Cho; Hyuk-Jae Chang; Ji Min Sung; Jinyong Lee; Hojin Ryoo; Chi Young Shim; Geu-Ru Hong; Namsik Chung
Journal:  J Cardiovasc Ultrasound       Date:  2016-09-26

7.  End-Stage Renal Disease Impairs the Multidirectional Movements of the Common Carotid Artery: Assessment Using Dimensional Speckle-Tracking Carotid Strain Ultrasonography.

Authors:  Sang-Eun Lee; Jinyong Lee; Tae-Hyun Yoo; In-Jeong Cho; Hyuk-Jae Chang
Journal:  J Cardiovasc Imaging       Date:  2018-09-17

8.  Robust myocardial motion tracking for echocardiography: variational framework integrating local-to-global deformation.

Authors:  Chi Young Ahn
Journal:  Comput Math Methods Med       Date:  2013-03-11       Impact factor: 2.238

9.  Modified optical flow technique for cardiac motions analysis in echocardiography images.

Authors:  Paria Torkashvand; Hamid Behnam; Zahra Alizadeh Sani
Journal:  J Med Signals Sens       Date:  2012-07

10.  Mathematical modeling of cardiac function to evaluate clinical cases in adults and children.

Authors:  Selim Bozkurt
Journal:  PLoS One       Date:  2019-10-31       Impact factor: 3.240

  10 in total