Literature DB >> 16443617

Laser surface modification of Ti--6Al--4V: wear and corrosion characterization in simulated biofluid.

Raghuvir Singh1, A Kurella, Narendra B Dahotre.   

Abstract

Laser surface melting (LSM) of Ti-6Al-4V is performed in argon to improve its properties, such as microstructure, corrosion, and wear for biomedical applications. Corrosion behavior is investigated by conducting electrochemical polarization experiments in simulated body fluid (Ringer's solution) at 37 C. Wear properties are evaluated in Ringer's solution using pin-on-disc apparatus at a slow speed. Untreated Ti-6Al-4V contains alpha+beta phase. After laser surface melting, it transforms to acicular alpha embedded in the prior beta matrix. Grain growth in the range of 65-89 microm with increase in laser power from 800 to 1500 W due to increase in associated temperature is observed. The hardness of as-laserprocessed Ti-6Al-4V alloy is more (275-297 HV) than that of the untreated alloy (254 HV). Passivation currents are significantly reduced to < 4.3 microA/cm2 after laser treatment compared to untreated Ti-6Al-4V (approximately 12 microA/cm2). The wear resistance of laser-treated Ti-6Al-4V in simulated body fluid is enhanced compared to that of the untreated one. It is the highest for the one that is processed at a laser power of 800 W. Typical micro-cutting features of abrasive wear is the prominent mechanism of wear in both untreated and as-laser-treated Ti-6Al-4V. Fragmentation of wear debris assisted by microcracking was responsible for mass loss during the wear of untreated Ti-6Al-4V in Ringer's solution.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16443617     DOI: 10.1177/0885328206055998

Source DB:  PubMed          Journal:  J Biomater Appl        ISSN: 0885-3282            Impact factor:   2.646


  6 in total

1.  Biomimetic transformations of amorphous calcium phosphate: kinetic and thermodynamic studies.

Authors:  D Rabadjieva; R Gergulova; R Titorenkova; S Tepavitcharova; E Dyulgerova; Chr Balarew; O Petrov
Journal:  J Mater Sci Mater Med       Date:  2010-06-09       Impact factor: 3.896

2.  Electrochemical and mechanical behavior of laser processed Ti-6Al-4V surface in Ringer's physiological solution.

Authors:  Raghuvir Singh; S K Tiwari; Suman K Mishra; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2011-06-10       Impact factor: 3.896

3.  Corrosion and corrosion-fatigue behavior of cp-Ti and Ti-6Al-4V laser-marked biomaterials.

Authors:  F J Gil; L Delgado; E Espinar; J M Llamas
Journal:  J Mater Sci Mater Med       Date:  2012-02-21       Impact factor: 3.896

4.  Biotribocorrosion of 3D-Printed silica-coated Ti6Al4V for load-bearing implants.

Authors:  Ali Afrouzian; Jose D Avila; Amit Bandyopadhyay
Journal:  J Mater Res       Date:  2021-07-13       Impact factor: 2.909

5.  Laser surface processing of Ti6Al4V in gaseous nitrogen: corrosion performance in physiological solution.

Authors:  Raghuvir Singh; S Ghosh Chowdhury; S K Tiwari; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2007-10-04       Impact factor: 3.896

Review 6.  Corrosion degradation and prevention by surface modification of biometallic materials.

Authors:  Raghuvir Singh; Narendra B Dahotre
Journal:  J Mater Sci Mater Med       Date:  2006-12-02       Impact factor: 4.727

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.