Literature DB >> 16441829

Comparison of side hole versus non side hole high flow hemodialysis catheters.

Michael G Tal1, Aldo J Peixoto, Susan T Crowley, Neil Denbow, Donna Eliseo, Jeffrey Pollak.   

Abstract

Current literature suggests that side holes may be detrimental to dialysis catheter performance. Today, these catheters are primarily available with side holes. The purpose of this study was to compare flow rates, infection rate, and survival of side hole vs. non side hole hemodialysis catheters. Over a 16-month period patients were arbitrarily assigned to either a 14.5 F MAHURKAR MAXID cuffed dual lumen tunneled catheter with side holes or a 14.5 F MAHURKAR MAXID cuffed dual lumen tunneled catheter without side holes ("non side hole catheters"). We performed a retrospective analysis of catheter flow rates, patency, catheter survival, and catheter-related infections. Information was gathered for the life of the catheter or up to 28 weeks. A total of 54 patients were enrolled in the study. Thirty-seven of 54 (68%) patients received a catheter with side holes for a total of 3,930 catheter days and 17/54 (32%) received a similar catheter without side holes for a total of 2,188 catheter days. Catheter infection necessitating removal of the catheter occurred in 10/37 catheters with side holes and 1/17 without side holes. Infection rates per 1,000 catheter days were 2.545 with side holes and 0.254 without side holes (p<0.001). Slightly improved catheter survival (p<0.05) was recorded with the non side hole catheters. No insertion complication (e.g., air embolization, bleeding, or kinking) occurred with either catheter. One catheter without side holes had to be repositioned 5 days after insertion because of poor flows. No significant difference was recorded in mean blood flow rates between the catheters. Results indicate reduced catheter infection rate in hemodialysis patients with the use of non side hole dual lumen tunneled cuffed catheters.

Entities:  

Mesh:

Year:  2006        PMID: 16441829     DOI: 10.1111/j.1542-4758.2006.01176.x

Source DB:  PubMed          Journal:  Hemodial Int        ISSN: 1492-7535            Impact factor:   1.812


  3 in total

1.  A review of evolving dialysis catheter technologies.

Authors:  Martha-Grace Knuttinen; Sonia Bobra; Julian Hardman; Ron C Gaba; James T Bui; Charles A Owens
Journal:  Semin Intervent Radiol       Date:  2009-06       Impact factor: 1.513

Review 2.  Hemodialysis Catheters: Update on Types, Outcomes, Designs and Complications.

Authors:  Husameddin El Khudari; Merve Ozen; Bridget Kowalczyk; Juri Bassuner; Ammar Almehmi
Journal:  Semin Intervent Radiol       Date:  2022-02-18       Impact factor: 1.513

3.  Dual-lumen catheters for continuous venovenous hemofiltration: limits for blood delivery via femoral vein access and a potential alternative in an experimental setting in anesthetized pigs.

Authors:  Juliane K Unger; Klaus Pietzner; Roland C Francis; Juergen Birnbaum; Marc Michael Theisen; Arne-Joern Lemke; Stefan M Niehues
Journal:  Crit Care       Date:  2007       Impact factor: 9.097

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.