Literature DB >> 16438234

High capacity implantable data recorders: system design and experience in canines and Denning black bears.

Timothy G Laske1, Henry J Harlow, Jon C Werder, Mark T Marshall, Paul A Iaizzo.   

Abstract

BACKGROUND: Implantable medical devices have increasingly large capacities for storing patient data as a diagnostic aid and to allow patient monitoring. Although these devices can store a significant amount of data, an increased ability for data storage was required for chronic monitoring in recent physiological studies. METHOD OF APPROACH: Novel high capacity implantable data recorders were designed for use in advanced physiological studies of canines and free-ranging black bears. These hermitically sealed titanium encased recorders were chronically implanted and programmed to record intrabody broadband electrical activity to monitor electrocardiograms and electromyograms, and single-axis acceleration to document relative activities.
RESULTS: Changes in cardiac T-wave morphology were characterized in the canines over a 6 month period, providing new physiological data for the design of algorithms and filtering schemes that could be employed to avoid inappropriate implantable defibrillator shocks. Unique characteristics of bear hibernation physiology were successfully identified in the black bears, including: heart rate, respiratory rate, gross body movement, and shiver An unanticipated high rejection rate of these devices occurred in the bears, with five of six being externalized during the overwintering period, including two devices implanted in the peritoneal cavity.
CONCLUSIONS: High capacity implantable data recorders were designed and utilized for the collection of long-term physiological data in both laboratory and extreme field environments. The devices described were programmable to accommodate the diverse research protocols. Additionally, we have described substantial differences in the response of two species to a common device. Variations in the foreign body response of different mammals must be identified and taken into consideration when choosing tissue-contacting materials in the application of biomedical technology to physiologic research.

Entities:  

Mesh:

Year:  2005        PMID: 16438234     DOI: 10.1115/1.2049340

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  6 in total

1.  A versatile telemetry system for continuous measurement of heart rate, body temperature and locomotor activity in free-ranging ruminants.

Authors:  Claudio Signer; Thomas Ruf; Franz Schober; Gerhard Fluch; Thomas Paumann; Walter Arnold
Journal:  Methods Ecol Evol       Date:  2010-03       Impact factor: 7.781

2.  Monitoring the wild black bear's reaction to human and environmental stressors.

Authors:  Timothy G Laske; David L Garshelis; Paul A Iaizzo
Journal:  BMC Physiol       Date:  2011-08-17

3.  Extreme respiratory sinus arrhythmia enables overwintering black bear survival--physiological insights and applications to human medicine.

Authors:  Timothy G Laske; Henry J Harlow; David L Garshelis; Paul A Iaizzo
Journal:  J Cardiovasc Transl Res       Date:  2010-05-01       Impact factor: 4.132

4.  Retention and loss of PIT tags and surgically implanted devices in the Eurasian beaver.

Authors:  Martin Mayer; Marianne Lian; Boris Fuchs; Christian A Robstad; Alina L Evans; Kathryn L Perrin; Eva M Greunz; Timothy G Laske; Jon M Arnemo; Frank Rosell
Journal:  BMC Vet Res       Date:  2022-06-10       Impact factor: 2.792

5.  Six Years in the Life of a Mother Bear - The Longest Continuous Heart Rate Recordings from a Free-Ranging Mammal.

Authors:  Timothy G Laske; Paul A Iaizzo; David L Garshelis
Journal:  Sci Rep       Date:  2017-01-17       Impact factor: 4.379

6.  Big data in wildlife research: remote web-based monitoring of hibernating black bears.

Authors:  Timothy G Laske; David L Garshelis; Paul A Iaizzo
Journal:  BMC Physiol       Date:  2014-12-11
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.