Literature DB >> 16436885

Microtextured materials for circulatory support devices: preliminary studies.

Conrad M Zapanta1, James W Griffith, Gerald D Hess, Bradley J Doxtater, Tigran Khalapyan, Walter E Pae, Gerson Rosenberg.   

Abstract

Thromboembolic events (TE) associated with circulatory support devices are a major source of mortality and morbidity. Clinically, the lowest TE rates are claimed with devices that incorporate textured blood-contacting materials. The textured materials currently used in circulatory assist devices are composed of small, attached fibers that form the boundaries of connected cavities. These cavities entrap blood components to form a "neointimal" layer, which is believed to minimize thromboembolic events. We believe that the three-dimensional surface topography of blood-contacting materials is a major controlling factor in the formation of a stable neointimal layer upon the material. Particle-cast cavities were used to form geometric features in segmented polyurethane. This microtextured material was incorporated as part of a flexible blood-contacting surface in a blood pump that was implanted as a left ventricular assist device in calves. The structure, thickness, stability, and development of the neointimal layer were then evaluated. These preliminary studies have shown that a stable neointimal layer can be formed upon the particle-cast surfaces. The results also indicate that the cavity size on the particle-cast surfaces has a significant effect on neointimal adhesion. The methods employed can be used in the design of future circulatory support devices.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16436885     DOI: 10.1097/01.mat.0000189726.87077.ad

Source DB:  PubMed          Journal:  ASAIO J        ISSN: 1058-2916            Impact factor:   2.872


  4 in total

1.  The effect of CD47 modified polymer surfaces on inflammatory cell attachment and activation.

Authors:  Stanley J Stachelek; Matthew J Finley; Ivan S Alferiev; Fengxiang Wang; Richard K Tsai; Edward C Eckells; Nancy Tomczyk; Jeanne M Connolly; Dennis E Discher; David M Eckmann; Robert J Levy
Journal:  Biomaterials       Date:  2011-03-22       Impact factor: 12.479

2.  Comparison of the Hemocompatibility of an Axial and a Centrifugal Left Ventricular Assist Device in an In Vitro Test Circuit.

Authors:  Patrick Borchers; Patrick Winnersbach; Sandra Kraemer; Christian Beckers; Eva Miriam Buhl; Steffen Leonhardt; Rolf Rossaint; Marian Walter; Thomas Breuer; Christian Bleilevens
Journal:  J Clin Med       Date:  2022-06-15       Impact factor: 4.964

3.  Hyaluronan and dextran modified tubes resist cellular activation with blood contact.

Authors:  David M Eckmann; Irene Y Tsai; Nancy Tomczyk; John W Weisel; Russell J Composto
Journal:  Colloids Surf B Biointerfaces       Date:  2013-02-26       Impact factor: 5.268

Review 4.  Control of Blood Coagulation by Hemocompatible Material Surfaces-A Review.

Authors:  Janna Kuchinka; Christian Willems; Dmitry V Telyshev; Thomas Groth
Journal:  Bioengineering (Basel)       Date:  2021-12-15
  4 in total