Literature DB >> 16435252

[Balloon-assisted percutaneous vertebroplasty in patients with osteoporotic vertebral body compression fractures--first results].

B U Schulte1, D Brücher, M Trompeter, C Remy, P Reimer.   

Abstract

PURPOSE: To determine the feasibility, efficacy and safety of balloon-assisted percutaneous vertebroplasty (BA-VP) in patients with osteoporotic vertebral compression fractures (VCFs).
MATERIALS AND METHODS: In 47 patients (29 women, 18 men; mean age: 70 years and 4 months) with severe VCFs, 66 BA-VPs were performed via a unipedicular access. After initial puncture (under combined fluoroscopy and CT guidance) of the vertebral body (VB), the needle was retraced by 1.5 cm, and a 12-mm Fogarty balloon catheter was introduced and inflated using 2-4 ml diluted contrast media (CM). After the subsequent removal of the catheter and repositioning of the needle, vertebroplasty was performed.
RESULTS: The mean volume of PMMA injected was 4.4 ml (2.5-7.2 ml). Pain reduction (measured by the Visual Analogue Scale) was achieved in 95 % of the patients, dropping from on average 8.0 pre-intervention to 2.2 after a mean follow-up of 8 months. A reduction of the pain relieving medication was achieved in 68 % of the cases and patient activity improved markedly. No severe or clinically relevant complications were observed. Cement leakage occurred by filling of epidural and paravertebral veins in 9.1 and 6.1 % of the cases, respectively. Leakage into the paravertebral soft tissues was seen in 3.0 % of the patients and to the adjacent disc space in 10.6 % of the cases.
CONCLUSION: Vertebroplasty and kyphoplasty are currently used to treat osteoporotic VCFs but show either a comparatively high leakage rate or are rather complex and expensive. Balloon-assisted vertebroplasty seems to combine advantages from both methods and is effective, safe and comparatively inexpensive.

Entities:  

Mesh:

Year:  2006        PMID: 16435252     DOI: 10.1055/s-2005-858829

Source DB:  PubMed          Journal:  Rofo        ISSN: 1438-9010


  3 in total

1.  Percutaneous balloon kyphoplasty with the patient under intravenous analgesia and sedation: a feasibility study.

Authors:  M Mohr; D Pillich; M Kirsch; J U Mueller; S Fleck; N Hosten; S Langner
Journal:  AJNR Am J Neuroradiol       Date:  2011-01-27       Impact factor: 3.825

2.  [CT-based analysis of cement distribution in unipedicular vertebroplasty].

Authors:  M Walz; E Esmer; B Kolbow
Journal:  Unfallchirurg       Date:  2006-11       Impact factor: 1.000

3.  CT-guided vertebroplasty in osteoprotic vertebral fractures: incidence of secondary fractures and impact of intradiscal cement leakages during follow-up.

Authors:  M B Pitton; S Herber; C Bletz; P Drees; N Morgen; U Koch; B Böhm; A Eckardt; C Düber
Journal:  Eur Radiol       Date:  2007-07-19       Impact factor: 5.315

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.