Literature DB >> 16435099

Atypical pulmonary embolism of port catheter fragments in oncology patients.

Alexey Surov1, Karin Jordan, Michael Buerke, Monica Persing, Bettina Wollschlaeger, Curd Behrmann.   

Abstract

GOALS OF WORK: Embolization of venous catheter fragments to the pulmonary vasculature is a very rare form of pulmonary embolism which is only sporadically reported in the literature. The incidence and clinical picture of this complication are unknown. PATIENT AND METHODS: In this retrospective analysis between 1999 and 2004, in our clinic, 1,014 port catheters were implanted. In this 5-year period, the patients' files were screened for the incidence of pulmonary embolism of catheter fragments and the accompanying complication rate. MAIN
RESULTS: In 11 patients, port catheter dislodgment and embolism into the pulmonary artery occurred. In all the patients' port examination by fluoroscopy, catheter dislocation and embolization were shown. In these 11 patients, no obvious clinical signs indicating dislocation of catheter fragments into the pulmonary circulation were found. None of these patients demonstrated respiratory symptoms. Heart rate, blood pressure, respiration frequency, and even oxygen saturation were normal. In 7 of the 11 patients, malfunction of port catheter was the first indicator of catheter dislocation. In four patients, embolized catheter fragments were an incidental finding. The main cause of catheter embolization was the pinch off syndrome. All embolized catheter fragments were retrieved by a 'goose-neck' snare without complication.
CONCLUSION: These results suggest that the migration of fractured catheter into the pulmonary artery occurs in 1% of the central port catheter implantation. It is often asymptomatic, and malfunction of the catheter may be the first sign of this complication. The pinch off syndrome might be prevented by using the internal jugular vein or by implantation of the port catheter more laterally in the subclavian vein.

Entities:  

Mesh:

Year:  2006        PMID: 16435099     DOI: 10.1007/s00520-005-0011-8

Source DB:  PubMed          Journal:  Support Care Cancer        ISSN: 0941-4355            Impact factor:   3.603


  24 in total

Review 1.  Thrombotic complications of central venous catheters in cancer patients.

Authors:  M Monreal; E Davant
Journal:  Acta Haematol       Date:  2001       Impact factor: 2.195

2.  [Pulmonary embolism after catheter break].

Authors:  H KNUTSON; K STENBERG
Journal:  Nord Med       Date:  1959-10-08

3.  Peripheral venous access ports: outcomes analysis in 109 patients.

Authors:  L J Bodner; J L Nosher; K M Patel; R L Siegel; R Biswal; C E Gribbin; R Tokarz
Journal:  Cardiovasc Intervent Radiol       Date:  2000 May-Jun       Impact factor: 2.740

4.  Catheter fragments embolization.

Authors:  J J Monsuez; M C Douard; Y Martin-Bouyer
Journal:  Angiology       Date:  1997-02       Impact factor: 3.619

5.  Right-sided valvular endocarditis supported by an unexpected intracardiac foreign body.

Authors:  M Balbi; G Bertero; S Bellotti; M L Rolandelli; S Caponnetto
Journal:  Chest       Date:  1990-06       Impact factor: 9.410

6.  The 'pinch-off phenomenon': a radiological symptom for potential fracture of an implanted permanent subclavian catheter system.

Authors:  J T Schlangen; J M Debets; J A Wils
Journal:  Eur J Radiol       Date:  1995-07       Impact factor: 3.528

7.  Totally implantable central venous access ports for long-term chemotherapy. A prospective study analyzing complications and costs of 333 devices with a minimum follow-up of 180 days.

Authors:  R Biffi; F de Braud; F Orsi; S Pozzi; S Mauri; A Goldhirsch; F Nolè; B Andreoni
Journal:  Ann Oncol       Date:  1998-07       Impact factor: 32.976

8.  The treatment and outcome of cancer patients with thromboses on central venous catheters.

Authors:  D A Frank; J Meuse; D Hirsch; J G Ibrahim; A D van den Abbeele
Journal:  J Thromb Thrombolysis       Date:  2000-12       Impact factor: 2.300

9.  Positional ventricular tachycardia from a fractured mediport catheter with right ventricular migration--a case report.

Authors:  Mamatha R Gowda; Ramesh M Gowda; Ijaz A Khan; Gopikrishna Punukollu; Sunil P Chand; Rhonda Bixon; Deborah L Reede
Journal:  Angiology       Date:  2004 Sep-Oct       Impact factor: 3.619

10.  Experience with subcutaneous infusion ports in three hundred patients.

Authors:  T E Brothers; L K Von Moll; J E Niederhuber; J A Roberts; S Walker-Andrews; W D Ensminger
Journal:  Surg Gynecol Obstet       Date:  1988-04
View more
  5 in total

1.  Successful removal of embolized chemoport catheter within the heart and pericardium: 3 case reports.

Authors:  Shin-Eui Yoon; Chang Hoon Lee
Journal:  J Thorac Dis       Date:  2017-08       Impact factor: 2.895

2.  Percutaneous retrieval of intravascular venous foreign bodies in children.

Authors:  Anne Marie Cahill; Deddeh Ballah; Paula Hernandez; Lucia Fontalvo
Journal:  Pediatr Radiol       Date:  2011-12-17

3.  Permcath catheter embolization: a case report.

Authors:  Hadi Yousefshahi; Payvand Bina; Fardin Yousefshahi
Journal:  Anesth Pain Med       Date:  2015-04-20

4.  Central venous catheter fracture during pacemaker lead extraction.

Authors:  Jacques Rizkallah; Glen Sumner; Robert Sheldon
Journal:  HeartRhythm Case Rep       Date:  2015-10-31

5.  Wandering Catheter Through Pulmonary Vasculature.

Authors:  Debbie Lee; Kitt Shaffer
Journal:  Radiol Case Rep       Date:  2015-11-06
  5 in total