Long-term follow-up of changes in fibrillation waves in patients with persistent atrial fibrillation: spectral analysis of surface ECG.

Takeshi Sasaki1, Shinichi Niwano, Sae Sasaki, Ryuta Imaki, Masaru Yuge, Shoji Hirasawa, Daisuke Satoh, Masahiko Moriguchi, Akira Fujiki, Tohru Izumi.   

Abstract

BACKGROUND: Little is known about the shortening of atrial refractoriness as a result of electrical remodeling in atrial fibrillation (AF) in clinical cases, especially in terms of long-term follow-up, because of a lack of noninvasive testing methods. METHODS AND
RESULTS: The present study population comprised 38 consecutive patients with persistent AF (PAF, >1 month). Before and after the follow-up period of 1-14 months, surface ECGs were recorded for analysis. In each case, the fibrillation wave was purified by subtracting the QRS-T complex template and then power spectral analysis was performed. The mean fibrillation cycle length (FCL) and FCL coefficient of variation (FCL-CV) were determined from peak power frequency in 20 epochs in each recording. The change in FCL (FCL) was calculated by subtracting the baseline FCL from the FCL after the follow-up period. To correct for the difference in the follow-up period, DeltaFCL was divided by the follow-up period in each case. In 38 cases, mean FCL decreased from 160+/-20 ms to 151+/-19 ms (p<0.05), and the FCL-CV also decreased from 15+/-9% to 12+/-5% (p<0.05). The corrected DeltaFCL was -2.4+/-7.6 (ms/month) and there was a significant negative correlation between corrected DeltaFCL and baseline FCL (p<0.01).
CONCLUSION: Shortening of the FCL during a relatively long-term follow-up period was observed in patients with PAF.

Entities:  

Mesh:

Year:  2006        PMID: 16434810     DOI: 10.1253/circj.70.169

Source DB:  PubMed          Journal:  Circ J        ISSN: 1346-9843            Impact factor:   2.993


  2 in total

1.  Electrophysiological characteristics associated with symptoms in pacemaker patients with paroxysmal atrial fibrillation.

Authors:  John Silberbauer; Rick A Veasey; Elizabeth Cheek; Nadeem Maddekar; Neil Sulke
Journal:  J Interv Card Electrophysiol       Date:  2009-07-28       Impact factor: 1.900

2.  Analysis of atrial fibrillatory activity from high-resolution surface electrocardiograms: Evaluation and application of a new system.

Authors:  Herko Grubitzsch; Diethelm Modersohn; Thomas Leuthold; Wolfgang Konertz
Journal:  Exp Clin Cardiol       Date:  2008
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.