Literature DB >> 16431067

Threshold-dependent variability of coronary artery calcification measurements -- implications for contrast-enhanced multi-detector row-computed tomography.

Fabian Moselewski1, Maros Ferencik, Stephan Achenbach, Suhny Abbara, Ricardo C Cury, Sarah L Booth, Ik-Kyung Jang, Thomas J Brady, Udo Hoffmann.   

Abstract

INTRODUCTION: The present study investigated the threshold-dependent variability of coronary artery calcification (CAC) measurements and the potential to quantify CAC in contrast-enhanced multi-detector row-computed tomography (MDCT).
METHODS: We compared the mean CT attenuation of CAC to luminal contrast enhancement of the coronary arteries in 30 patients (n = 30) undergoing standard coronary contrast-enhanced spiral MDCT. The modified Agatston score [AS], calcified plaque volume [CV], and mineral mass [MM]) at four different thresholds (130, 200, 300, and 400 HU) were measured in 50 patients who underwent non-contrast-enhanced MDCT.
RESULTS: Mean CT attenuation of CAC was similar to the attenuation of the contrast-enhanced coronary lumen (CAC 297.1 +/- 68.7 HU versus 295 +/- 65 HU (p < 0.0001), respectively). Above a threshold of 300 HU CAC measurements significantly varied to standard measurements obtained at a threshold of 130 HU (p < 0.0001). The threshold-dependent variation of MM measurements was significantly smaller than for AS and CV (130 HU versus 400 HU: 63, 75, and 81, respectively; p < 0.001). These differences resulted in a change of age and gender based percentile category for AS in 78% of subjects. DISCUSSION: We demonstrated that CAC measurements are threshold dependent with MM measurements having significantly less variation than AS or CV. Due to the similarity of mean CT attenuation of CAC and the contrast-enhanced coronary lumen accurate quantification of CAC may be difficult in standard coronary contrast-enhanced spiral MDCT.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16431067     DOI: 10.1016/j.ejrad.2005.12.026

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  7 in total

1.  Fully automatic model-based calcium segmentation and scoring in coronary CT angiography.

Authors:  Dov Eilot; Roman Goldenberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-08       Impact factor: 2.924

2.  Motion-corrected coronary calcium scores by a convolutional neural network: a robotic simulating study.

Authors:  Yaping Zhang; Niels R van der Werf; Beibei Jiang; Robbert van Hamersvelt; Marcel J W Greuter; Xueqian Xie
Journal:  Eur Radiol       Date:  2019-10-18       Impact factor: 5.315

3.  Visual and automatic grading of coronary artery stenoses with 64-slice CT angiography in reference to invasive angiography.

Authors:  Stephanie Busch; Thorsten R C Johnson; Konstantin Nikolaou; Franz von Ziegler; Andreas Knez; Maximilian F Reiser; Christoph R Becker
Journal:  Eur Radiol       Date:  2006-12-16       Impact factor: 5.315

4.  Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study.

Authors:  Jaap M Groen; Marcel J W Greuter; R Vliegenthart; C Suess; B Schmidt; F Zijlstra; M Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-11-23       Impact factor: 2.357

5.  Fully automated derivation of coronary artery calcium scores and cardiovascular risk assessment from contrast medium-enhanced coronary CT angiography studies.

Authors:  Ullrich Ebersberger; Dov Eilot; Roman Goldenberg; Alon Lev; J Reid Spears; Garrett W Rowe; Nicholas Y Gallagher; William T Halligan; Philipp Blanke; Marcus R Makowski; Aleksander W Krazinski; Justin R Silverman; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2012-09-16       Impact factor: 5.315

6.  CT attenuation values of blood and myocardium: rationale for accurate coronary artery calcifications detection with multi-detector CT.

Authors:  Salah D Qanadli; Anne-Marie Jouannic; Jamshid Dehmeshki; Tri-Linh Lu
Journal:  PLoS One       Date:  2015-04-14       Impact factor: 3.240

7.  Coronary calcium scoring with partial volume correction in anthropomorphic thorax phantom and screening chest CT images.

Authors:  Jurica Šprem; Bob D de Vos; Nikolas Lessmann; Robbert W van Hamersvelt; Marcel J W Greuter; Pim A de Jong; Tim Leiner; Max A Viergever; Ivana Išgum
Journal:  PLoS One       Date:  2018-12-20       Impact factor: 3.240

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.