Bispectral index-controlled anaesthesia for electroconvulsive therapy.

R Hanss1, M Bauer, B Bein, R Goeder, B Buttgereit, A C Schulz-Du Bois, M Steinfath, J Scholz.   

Abstract

BACKGROUND: The suggested induction dose of methohexital for electroconvulsive therapy (ECT) varies widely influencing efficacy of ECT and safety of anaesthesia. Bispectral index (BIS), a monitor of consciousness, may be useful to assure adequate hypnosis with optimized methohexital dose.
METHODS: Patients with medically resistant major depression (ICD10), scheduled for multiple ECT's, were studied. Depth of anaesthesia was BIS controlled. ECT was not performed until BIS dropped below 50. Initially anaesthesia was induced with methohexital 1.0 mg kg(-1), and stepwise reduced by 0.1 mg kg(-1) during consecutive treatments. If BIS did not drop below 50, the methohexital was supplemented by further boluses of 0.5 mg kg(-1), until the desired level of hypnosis was reached. The adequacy of the anaesthetic recommendation for methohexital (1.0-1.5 mg kg(-1)) as well as the psychiatric recommendation (0.75-1 mg kg(-1)) was investigated.
RESULTS: One-hundred and nine ECT's in 14 patients were studied. The recommended anaesthetic dose (1.0-1.5 mg kg(-1)) was inadequate in 40% of the treatments, with 12% exceeding 1.5 mg kg(-1), and 28% below 1.0 mg kg(-1). Psychiatric recommendation (0.75-1.0 mg kg(-1)) was inadequate in 49%, with 39% exceeding 1.0 mg kg(-1) and 10% undershooting at 0.75 mg kg(-1).
CONCLUSIONS: Methohexital for ECT showed a great variability, exceeding as well as undershooting the dosage recommendations widely. BIS monitoring may be useful to secure adequate hypnosis during muscle relaxation and treatment and may optimize ECT efficacy.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16430791     DOI: 10.1017/S026502150500219X

Source DB:  PubMed          Journal:  Eur J Anaesthesiol        ISSN: 0265-0215            Impact factor:   4.330


  2 in total

Review 1.  [Anesthesia for electroconvulsive therapy].

Authors:  U Grundmann; S O Schneider
Journal:  Anaesthesist       Date:  2013-04       Impact factor: 1.041

2.  The Alaris auditory evoked potential monitor as an indicator of seizure inducibility and duration during electroconvulsive therapy: an observational study.

Authors:  Hsing-Hao Huang; Chun-Yu Wu; Feng-Sheng Lin; Yi-Ping Wang; Wei-Zen Sun; Chih-Peng Lin; Shou-Zen Fan
Journal:  BMC Anesthesiol       Date:  2014-05-13       Impact factor: 2.217

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.