Literature DB >> 16428050

Multiphase contrast medium injection for optimization of computed tomographic coronary angiography.

Matthew Jay Budoff1, Jerold S Shinbane, Janis Child, Sivi Carson, Alex Chau, Stephen H Liu, SongShou Mao.   

Abstract

RATIONALE AND
OBJECTIVES: Electron beam angiography is a minimally invasive imaging technique. Adequate vascular opacification throughout the study remains a critical issue for image quality. We hypothesized that vascular image opacification and uniformity of vascular enhancement between slices can be improved using multiphase contrast medium injection protocols.
MATERIALS AND METHODS: We enrolled 244 consecutive patients who were randomized to three different injection protocols: single-phase contrast medium injection (Group 1), dual-phase contrast medium injection with each phase at a different injection rate (Group 2), and a three-phase injection with two phases of contrast medium injection followed by a saline injection phase (Group 3). Parameters measured were aortic opacification based on Hounsfield units and uniformity of aortic enhancement at predetermined slices (locations from top [level 1] to base [level 60]).
RESULTS: In Group 1, contrast opacification differed across seven predetermined locations (scan levels: 1st versus 60th, P < .05), demonstrating significant nonuniformity. In Group 2, there was more uniform vascular enhancement, with no significant differences between the first 50 slices (P > .05). In Group 3, there was greater uniformity of vascular enhancement and higher mean Hounsfield units value across all 60 images, from the aortic root to the base of the heart (P < .05).
CONCLUSIONS: The three-phase injection protocol improved vascular opacification at the base of the heart, as well as uniformity of arterial enhancement throughout the study.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16428050     DOI: 10.1016/j.acra.2005.09.087

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  2 in total

1.  Normal thoracic aorta diameter on cardiac computed tomography in healthy asymptomatic adults: impact of age and gender.

Authors:  Song Shou Mao; Nasir Ahmadi; Birju Shah; Daniel Beckmann; Annie Chen; Luan Ngo; Ferdinand R Flores; Yan Lin Gao; Matthew J Budoff
Journal:  Acad Radiol       Date:  2008-07       Impact factor: 3.173

2.  CT artifacts after contrast media injection in chest imaging: evaluation of post-processing algorithms, virtual monoenergetic images and their combination for artifact reduction.

Authors:  Amit Gupta; Verena Carola Obmann; Michelle Jordan; Simon Lennartz; Markus Michael Obmann; Nils Große Hokamp; David Zopfs; Lenhard Pennig; Gina Fürtjes; Nikhil Ramaiya; Robert Gilkeson; Kai Roman Laukamp
Journal:  Quant Imaging Med Surg       Date:  2021-01
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.