| Literature DB >> 16427881 |
Peirong Yu1, Gary L Clayman, Garrett L Walsh.
Abstract
Reconstruction of large tracheal defects has been largely unsuccessful. We report a novel single-stage tracheal reconstruction for a 6.5-cm long defect involving the anterior two thirds of the tracheal circumference in a patient with deeply infiltrative thyroid cancer into the tracheal lumen. The reconstruction was completed using a conduit composed of a radial forearm free flap for lining with a combined PolyMax mesh (Synthes, Paoli, PA) and Hemashield vascular graft (Boston Scientific, Natick, MA) for rigid support. At a 6-month follow-up the patient has normal swallowing and preoperative voice quality, and she maintains a patent, non-stented airway.Entities:
Mesh:
Year: 2006 PMID: 16427881 DOI: 10.1016/j.athoracsur.2004.12.009
Source DB: PubMed Journal: Ann Thorac Surg ISSN: 0003-4975 Impact factor: 4.330