Literature DB >> 16426214

Comparison of ultrasonographic characteristics of the thyroid gland in healthy small-, medium-, and large-breed dogs.

Catharina Brömel1, Rachel E Pollard, Philip H Kass, Valerie F Samii, Autumn P Davidson, Richard W Nelson.   

Abstract

OBJECTIVE: To determine ultrasonographic characteristics of the thyroid gland in healthy small-, medium-, and large-breed dogs and evaluate the relationships of thyroid gland size and volume with body weight and body surface area (BSA). ANIMALS: 72 dogs of small (6 Toy and 6 Miniature Poodles), medium (12 Beagles), and large breeds (12 Akitas and 36 Golden Retrievers). PROCEDURE: Each dog's thyroid gland was examined ultrasonographically with a 10- to 5-MHz multifrequency linear-array transducer. Size, shape, echogenicity, and homogeneity of thyroid lobes were evaluated on longitudinal and transverse images. Thyroid lobe volume was estimated by use of the equation for an ellipsoid (pi/6 [length x height x width]).
RESULTS: Thyroid lobes appeared fusiform or elliptical on longitudinal images and triangular or round to oval on transverse images. In most dogs, thyroid lobes were hyperechoic or isoechoic, compared with surrounding musculature, and had a homogeneous echogenic pattern. Mean length, width, height, and volume of thyroid lobes were significantly greater in Akitas and Golden Retrievers, compared with findings in Beagles or Poodles; mean length, width, and height were significantly greater in Beagles, compared with findings in Poodles. Total thyroid gland volume correlated with body weight (r = 0.73) and BSA (r = 0.74). CONCLUSIONS AND CLINICAL RELEVANCE: Among the dog breeds examined ultrasonographically, thyroid lobe size and volume were more variable than shape, echogenicity, and homogeneity. The correlation of thyroid gland volume with BSA suggests that size of the dog, rather than breed, should be considered when assessing thyroid glands ultrasonographically.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16426214     DOI: 10.2460/ajvr.67.1.70

Source DB:  PubMed          Journal:  Am J Vet Res        ISSN: 0002-9645            Impact factor:   1.156


  2 in total

1.  A comparison of portable ultrasound and fully-equipped clinical ultrasound unit in the thyroid size measurement of the Indo-Pacific bottlenose dolphin.

Authors:  Brian C W Kot; Michael T C Ying; Fiona M Brook
Journal:  PLoS One       Date:  2012-01-17       Impact factor: 3.240

2.  An area ratio of thyroid gland to common carotid artery for evaluating the thyroid gland size.

Authors:  Noboru Sasaki; Noriyuki Nagata; Keitaro Morishita; Tatsuyuki Osuga; Kazuyoshi Sasaoka; Nozomu Yokoyama; Hiroshi Ohta; Mitsuyoshi Takiguchi
Journal:  J Vet Med Sci       Date:  2020-06-04       Impact factor: 1.267

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.