Literature DB >> 16424573

Dosimetric effects on the penumbra region of irregular multi-leaf collimated fields.

James C L Chow1, Brent Wettlaufer, Runqing Jiang.   

Abstract

The dosimetric effect in the penumbra region for multi-leaf collimator (MLC) fields was studied using a Varian 21 EX linear accelerator. The beam profiles in the cross-line and in-line directions for MLC field configurations of varying lengths of protruded leaves, which are adjacent (on one or both sides) to the beam profile axes, were measured using a 6 MV photon beam. It was found that there is a decrease of dose in the 'edge' region of the protruded leaves' side in the cross-line profile, when the protruded leaves (upper and/or lower side) were moved out from 0.5 cm to 3 cm towards the central beam axis. When both the upper and lower portions of leaves were moved out forming a gap for the profile, the dose at the 'edge' region in the cross-line direction was decreased by about 20% and 6%, with the protruded length of leaves being 0.5 cm and 1 cm, respectively. The penumbra width of the cross-line profile increased with the protruded length of leaves when the gap width was 0.5 cm, and it was independent of the length when the width was increased larger than 1 cm. The Pinnacle treatment planning system could calculate the decrease of dose observed experimentally in the cross-line profile, but an underestimation of about 30% was found when using version 6.2b, which did not consider the leaf rounded end and tongue-and-groove effect. While the newly commissioned 7.4f, which considered the two aforementioned effects, made an improvement, it still underestimated the dose by 25% compared to the measurement. For the in-line profiles, both versions estimated the penumbra width well.

Mesh:

Year:  2006        PMID: 16424573     DOI: 10.1088/0031-9155/51/3/N01

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  3 in total

1.  Comparison of dosimetric characteristics of 120-leaf and 80-leaf multi-leaf collimators in a Varian linear accelerator for a 6-MV photon beam.

Authors:  R Mohan; K Jayesh; R C Joshi; P Narayanamurthy; Saroj Kumar Das Majumdar; Maha Al-Idirisi
Journal:  Radiol Phys Technol       Date:  2008-07-15

2.  Dosimetric evaluation of 120-leaf multileaf collimator in a Varian linear accelerator with 6-MV and 18-MV photon beams.

Authors:  R Mohan; K Jayesh; R C Joshi; Maha Al-Idrisi; P Narayanamurthy; Saroj Kumar Das Majumdar
Journal:  J Med Phys       Date:  2008-07

3.  SWIMRT: a graphical user interface using sliding window algorithm to construct a fluence map machine file.

Authors:  James C L Chow; Grigor N Grigorov; Nuri Yazdani
Journal:  J Appl Clin Med Phys       Date:  2006-05-25       Impact factor: 2.102

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.