Literature DB >> 16424249

Three-dimensional US of the fetus: volume imaging.

Beryl R Benacerraf1, Thomas D Shipp, Bryann Bromley.   

Abstract

PURPOSE: To retrospectively compare the rapidity, efficiency, and accuracy of three-dimensional (3D) and two-dimensional (2D) ultrasonography (US) for complete anatomic survey in fetuses at 17-21 weeks of gestation.
MATERIALS AND METHODS: Institutional review board approval was obtained, informed consent was waived, and the study was HIPAA compliant. Fifty consecutive women undergoing fetal anatomic survey at 17-21 weeks of gestation formed the study cohort. After standard 2D US was performed by one of eight sonographers, the same sonographer also obtained five 3D volumes to encompass the entire fetal anatomy. Three physicians interpreting the scans independently evaluated the completeness of the examination and time needed to read the scans, comparing the standard 2D method with the 3D volume reconstruction technique. The paired t test was used to compare biparietal diameter (BPD), femur length, and performance times between the 3D measurements and the 2D measurement. The t test was used to compare fetal anatomy according to volume angle. Differences were significant when P < .05.
RESULTS: Mean time to perform 2D US was 19.6 minutes per examination, whereas mean time to perform complete 3D volume acquisition was 1.8 minutes. Mean times needed to interpret 3D images and measure the BPD and femur were 5.53, 4.79, and 5.34 minutes for the three interpreting physicians. Compared with complete fetal surveys performed with 2D US, individual fetal anatomic landmarks (except for fetal arms and cavum septum pellucidum) were identified more than 94% of the time by using 3D US. Grouping anatomic views by region, the heart, head, extremities, and abdominal views were completely seen in 88%, 90%, 90%, and 95% of patients, respectively. No significant difference was seen between the three physicians regarding completeness of the 3D examinations (P = .7). One fetus had multiple anomalies, with 3D volumes identified as abnormal by all three physicians. Overall, 74% of 3D BPD measurements were within 1 mm of the 2D measurements, and 64% of 3D femur measurements were within 1 mm of the 2D measurements.
CONCLUSION: The standard fetal anatomic survey can be performed in less than 2 minutes with 3D volume US, and the volumes can be interpreted in 6-7 minutes, compared with a mean of 19.6 minutes to perform standard 2D US. Copyright RSNA, 2006.

Entities:  

Mesh:

Year:  2006        PMID: 16424249     DOI: 10.1148/radiol.2383050636

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  14 in total

1.  The benefits of 3D-4D fetal echocardiography.

Authors:  Cringu Ionescu
Journal:  Maedica (Buchar)       Date:  2010-01

2.  Off-site evaluation of three-dimensional ultrasound for the diagnosis of thyroid nodules: comparison with two-dimensional ultrasound.

Authors:  Soo Chin Kim; Ji-Hoon Kim; Seung Hong Choi; Tae Jin Yun; Jae Yeon Wi; Sun Ah Kim; Hye Young Sun; Inseon Ryoo; Sun-Won Park; Chul-Ho Sohn
Journal:  Eur Radiol       Date:  2016-01-22       Impact factor: 5.315

3.  Ultrasound: a strategic issue for radiology?

Authors:  Lorenzo E Derchi; Michel Claudon
Journal:  Eur Radiol       Date:  2008-08-15       Impact factor: 5.315

Review 4.  The future of pediatric US.

Authors:  Brian D Coley
Journal:  Pediatr Radiol       Date:  2011-04-27

5.  Volume US of the urinary tract in pediatric patients-a pilot study.

Authors:  Luís F Gonçalves; Aparna Joshi; Swati Mody; J Michael Zerin
Journal:  Pediatr Radiol       Date:  2011-05-13

6.  What does 2-dimensional imaging add to 3- and 4-dimensional obstetric ultrasonography?

Authors:  Luís F Gonçalves; Jyh Kae Nien; Jimmy Espinoza; Juan Pedro Kusanovic; Wesley Lee; Betsy Swope; Eleazar Soto; Marjorie C Treadwell; Roberto Romero
Journal:  J Ultrasound Med       Date:  2006-06       Impact factor: 2.153

Review 7.  Fetal evaluation of spine dysraphism.

Authors:  Dorothy Bulas
Journal:  Pediatr Radiol       Date:  2010-04-30

8.  A comparison of standard two-dimensional ultrasound to three-dimensional volume sonography for routine second-trimester fetal imaging.

Authors:  M E Roy-Lacroix; F Moretti; Z M Ferraro; L Brosseau; J Clancy; K Fung-Kee-Fung
Journal:  J Perinatol       Date:  2017-01-26       Impact factor: 2.521

9.  Diagnosis of gallbladder problems using three-dimensional ultrasound.

Authors:  Ben Stenberg; Simon Elliott
Journal:  Eur Radiol       Date:  2009-09-30       Impact factor: 5.315

10.  Comparison of Fetal Nuchal Fold Thickness Measurements by Two- and Three-Dimensional Ultrasonography (3DXI Multislice View).

Authors:  Leonardo da Silva Valladão de Freitas; Fernanda Silveira de Bello Barros; Rômulo Negrini; Luiz Cláudio de Silva Bussamra; Edward Araujo Júnior; Sebastião Piato; Luciano Marcondes Machado Nardozza; Antonio Fernandes Moron; Tsutomu Aoki
Journal:  Obstet Gynecol Int       Date:  2012-02-20
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.