Literature DB >> 16423901

Amplicon DNA melting analysis for mutation scanning and genotyping: cross-platform comparison of instruments and dyes.

Mark G Herrmann1, Jacob D Durtschi, L Kathryn Bromley, Carl T Wittwer, Karl V Voelkerding.   

Abstract

BACKGROUND: DNA melting analysis for genotyping and mutation scanning of PCR products by use of high-resolution instruments with special "saturation" dyes has recently been reported. The comparative performance of other instruments and dyes has not been evaluated.
METHODS: A 110-bp fragment of the beta-globin gene including the sickle cell anemia locus (A17T) was amplified by PCR in the presence of either the saturating DNA dye, LCGreen Plus, or SYBR Green I. Amplicons of 3 different genotypes (wild-type, heterozygous, and homozygous mutants) were melted on 9 different instruments (ABI 7000 and 7900HT, Bio-Rad iCycler, Cepheid SmartCycler, Corbett Rotor-Gene 3000, Idaho Technology HR-1 and LightScanner, and the Roche LightCycler 1.2 and LightCycler 2.0) at a rate of 0.1 degrees C/s or as recommended by the manufacturer. The ability of each instrument/dye combination to genotype by melting temperature (Tm) and to scan for heterozygotes by curve shape was evaluated.
RESULTS: Resolution varied greatly among instruments with a 15-fold difference in Tm SD (0.018 to 0.274 degrees C) and a 19-fold (LCGreen Plus) or 33-fold (SYBR Green I) difference in the signal-to-noise ratio. These factors limit the ability of most instruments to accurately genotype single-nucleotide polymorphisms by amplicon melting. Plate instruments (96-well) showed the greatest variance with spatial differences across the plates. Either SYBR Green I or LCGreen Plus could be used for genotyping by T(m), but only LCGreen Plus was useful for heterozygote scanning. However, LCGreen Plus could not be used on instruments with an argon laser because of spectral mismatch. All instruments compatible with LCGreen Plus were able to detect heterozygotes by altered melting curve shape. However, instruments specifically designed for high-resolution melting displayed the least variation, suggesting better scanning sensitivity and specificity.
CONCLUSION: Different instruments and dyes vary widely in their ability to genotype homozygous variants and scan for heterozygotes by whole-amplicon melting analysis.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16423901     DOI: 10.1373/clinchem.2005.063438

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  68 in total

1.  High resolution melting curve analysis of DNA sequence alterations of various sizes.

Authors:  Péter Becságh; Katalin Varga; Orsolya Szakács; László Kopper; Zsolt Orosz
Journal:  Pathol Oncol Res       Date:  2010-05-19       Impact factor: 3.201

2.  High-resolution melt curve analysis for identification of single nucleotide mutations in the quinolone resistance gene aac(6')-Ib-cr.

Authors:  Carlos Hidalgo-Grass; Jacob Strahilevitz
Journal:  Antimicrob Agents Chemother       Date:  2010-05-24       Impact factor: 5.191

3.  Rapid detection of isoniazid, rifampin, and ofloxacin resistance in Mycobacterium tuberculosis clinical isolates using high-resolution melting analysis.

Authors:  Xiaoyou Chen; Fanrong Kong; Qinning Wang; Chuanyou Li; Jianyuan Zhang; Gwendolyn L Gilbert
Journal:  J Clin Microbiol       Date:  2011-08-10       Impact factor: 5.948

4.  Unlabeled oligonucleotides as internal temperature controls for genotyping by amplicon melting.

Authors:  Michael T Seipp; Jacob D Durtschi; Michael A Liew; Jamie Williams; Kristy Damjanovich; Genevieve Pont-Kingdon; Elaine Lyon; Karl V Voelkerding; Carl T Wittwer
Journal:  J Mol Diagn       Date:  2007-07       Impact factor: 5.568

5.  High-resolution melting analysis for a reliable and two-step scanning of mutations in the tyrosine kinase domain of the chimerical bcr-abl gene.

Authors:  Yuko Doi; Daisuke Sasaki; Chiharu Terada; Sayaka Mori; Kazuto Tsuruda; Emi Matsuo; Yasushi Miyazaki; Kazuhiro Nagai; Hiroo Hasegawa; Katsunori Yanagihara; Yasuaki Yamada; Shimeru Kamihira
Journal:  Int J Hematol       Date:  2009-05-23       Impact factor: 2.490

6.  LightCycler technology in molecular diagnostics.

Authors:  Elaine Lyon; Carl T Wittwer
Journal:  J Mol Diagn       Date:  2009-02-05       Impact factor: 5.568

7.  High resolution melting analysis of almond SNPs derived from ESTs.

Authors:  Shu-Biao Wu; Michelle G Wirthensohn; Peter Hunt; John P Gibson; Margaret Sedgley
Journal:  Theor Appl Genet       Date:  2008-09-10       Impact factor: 5.699

8.  Denaturation-Enhanced Droplet Digital PCR for Liquid Biopsies.

Authors:  Mariana Fitarelli-Kiehl; Fangyan Yu; Ravina Ashtaputre; Ka Wai Leong; Ioannis Ladas; Julianna Supplee; Cloud Paweletz; Devarati Mitra; Jonathan D Schoenfeld; Sareh Parangi; G Mike Makrigiorgos
Journal:  Clin Chem       Date:  2018-10-01       Impact factor: 8.327

9.  Sensitive and specific KRAS somatic mutation analysis on whole-genome amplified DNA from archival tissues.

Authors:  Ronald van Eijk; Marjo van Puijenbroek; Amiet R Chhatta; Nisha Gupta; Rolf H A M Vossen; Esther H Lips; Anne-Marie Cleton-Jansen; Hans Morreau; Tom van Wezel
Journal:  J Mol Diagn       Date:  2009-12-03       Impact factor: 5.568

10.  High resolution melting analysis for gene scanning.

Authors:  Maria Erali; Carl T Wittwer
Journal:  Methods       Date:  2010-01-18       Impact factor: 3.608

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.