Literature DB >> 16423539

Reliability of electromyographic normalization methods for evaluating the hip musculature.

Lori A Bolgla1, Timothy L Uhl.   

Abstract

The purpose of this study was to determine the reliability of three normalization methods for analyzing hip abductor activation during rehabilitation exercises. Thirteen healthy subjects performed three open kinetic chain and three closed kinetic chain hip abductor exercises. Surface EMG activity for the gluteus medius was collected during each exercise and normalized based on a maximum voluntary isometric contraction (MVIC), mean dynamic (m-DYN), and peak dynamic activity (pk-DYN). Intraclass coefficient correlations (ICCs), intersubject coefficients of variation (CVs), and intrasubject CVs were then calculated for each normalization method. MVIC ICCs exceeded 0.93 for all exercises. M-DYN and pk-DYN ICCs exceeded 0.85 for all exercises except for the sidelying abduction exercise. Intersubject CVs ranged from 55% to 77% and 19% to 61% for the MVIC and dynamic methods, respectively. Intrasubject CVs ranged from 11% to 22% for all exercises under all normalization methods. The MVIC method provided the highest measurement reliability for determining differences in activation amplitudes between hip abductor exercises in healthy subjects. Future research should determine if these same results would apply to a symptomatic patient population.

Entities:  

Mesh:

Year:  2006        PMID: 16423539     DOI: 10.1016/j.jelekin.2005.11.007

Source DB:  PubMed          Journal:  J Electromyogr Kinesiol        ISSN: 1050-6411            Impact factor:   2.368


  32 in total

1.  Comparison of EMG Activity between Single-Leg Deadlift and Conventional Bilateral Deadlift in Trained Amateur Athletes - An Empirical Analysis.

Authors:  Wiktor Diamant; Stephan Geisler; Tim Havers; Axel Knicker
Journal:  Int J Exerc Sci       Date:  2021-04-01

2.  Electromyographic analysis of the three subdivisions of gluteus medius during weight-bearing exercises.

Authors:  Kieran O'Sullivan; Sharon M Smith; David Sainsbury
Journal:  Sports Med Arthrosc Rehabil Ther Technol       Date:  2010-07-12

3.  Textile Electrodes Embedded in Clothing: A Practical Alternative to Traditional Surface Electromyography when Assessing Muscle Excitation during Functional Movements.

Authors:  Steffi L Colyer; Polly M McGuigan
Journal:  J Sports Sci Med       Date:  2018-03-01       Impact factor: 2.988

4.  A comparison of a maximum exertion method and a model-based, sub-maximum exertion method for normalizing trunk EMG.

Authors:  Jacek Cholewicki; Jaap van Dieën; Angela S Lee; N Peter Reeves
Journal:  J Electromyogr Kinesiol       Date:  2011-06-12       Impact factor: 2.368

5.  DYNAMIC HIP ADDUCTION, ABDUCTION AND ABDOMINAL EXERCISES FROM THE HOLMICH GROIN-INJURY PREVENTION PROGRAM ARE INTENSE ENOUGH TO BE CONSIDERED STRENGTHENING EXERCISES - A CROSS-SECTIONAL STUDY.

Authors:  Kasper Krommes; Thomas Bandholm; Markus D Jakobsen; Lars L Andersen; Andreas Serner; Per Hölmich; Kristian Thorborg
Journal:  Int J Sports Phys Ther       Date:  2017-06

6.  Hip-abductor fatigue and single-leg landing mechanics in women athletes.

Authors:  Mary F Patrek; Thomas W Kernozek; John D Willson; Glenn A Wright; Scott T Doberstein
Journal:  J Athl Train       Date:  2011 Jan-Feb       Impact factor: 2.860

7.  Resisted Side Stepping: The Effect of Posture on Hip Abductor Muscle Activation.

Authors:  Justin W Berry; Theresa S Lee; Hanna D Foley; Cara L Lewis
Journal:  J Orthop Sports Phys Ther       Date:  2015-07-10       Impact factor: 4.751

8.  Hip muscle activity during 3 side-lying hip-strengthening exercises in distance runners.

Authors:  Joseph M McBeth; Jennifer E Earl-Boehm; Stephen C Cobb; Wendy E Huddleston
Journal:  J Athl Train       Date:  2012 Jan-Feb       Impact factor: 2.860

9.  AN EXAMINATION OF THE GLUTEAL MUSCLE ACTIVITY ASSOCIATED WITH DYNAMIC HIP ABDUCTION AND HIP EXTERNAL ROTATION EXERCISE: A SYSTEMATIC REVIEW.

Authors:  Paul Macadam; John Cronin; Bret Contreras
Journal:  Int J Sports Phys Ther       Date:  2015-10

10.  Electromyographic Study of a Sequence of Yau-Man Kung Fu Palm Strikes with and without Impact.

Authors:  Osmar Pinto Neto; Marcio Magini; Marcos T T Pacheco
Journal:  J Sports Sci Med       Date:  2007-10-01       Impact factor: 2.988

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.