Literature DB >> 16421258

Evaluation of scatter dose of dental titanium implants exposed to photon beams of different energies and irradiation angles in head and neck radiotherapy.

M Beyzadeoglu1, B Dirican, K Oysul, J Ozen, O Ucok.   

Abstract

OBJECTIVES: In this study, quantification of backscatter doses between scattering titanium dental implant and the thermoluminescent dosimeter (TLD(100)) radiation detector at axial beam irradiation-angle range of 0-90 degrees in head and neck radiotherapy is done to evaluate irradiation angle dependency of dose enhancement contributing to osteoradionecrosis.
METHODS: A cylindrical titanium dental implant with diameter of 4 mm and length of 9 mm was implanted into a specially-designed human mandible phantom with a TLD100 chip placed on the buccal site and irradiated with 6 MV X, 25 MV X and Co-60 gamma sources at 19 different irradiation angles.
RESULTS: Dose enhancement on a buccal site of the titanium implant depends on the incident beam angle. At angles of 65 degrees, 60 degrees and 40 degrees the maximum detected scatter doses over the titanium implant are 36%, 32% and 23% for Co-60 gamma, 6 MV X-ray and 25 MV X-ray, respectively. The dose enhancement at different beam angles was less pronounced in 25 MV X and more pronounced in Co-60 gamma irradiation.
CONCLUSIONS: For the different radiation beams studied, the irradiation angle between scattering titanium dental implants and the central axis does not significantly affect the total dose that may lead to osteoradionecrosis of the mandible.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16421258     DOI: 10.1259/dmfr/28125805

Source DB:  PubMed          Journal:  Dentomaxillofac Radiol        ISSN: 0250-832X            Impact factor:   2.419


  5 in total

1.  Dose distribution near thin titanium plate for skull fixation irradiated by a 4-MV photon beam.

Authors:  Tomohiro Shimozato; Keisuke Yasui; Ryota Kawanami; Kousaku Habara; Yuichi Aoyama; Katsuyoshi Tabushi; Yasunori Obata
Journal:  J Med Phys       Date:  2010-04

2.  A case of peri-implantitis and osteoradionecrosis arising around dental implants placed before radiation therapy.

Authors:  Yuji Teramoto; Hiroshi Kurita; Takahiro Kamata; Hitoshi Aizawa; Nobuhiko Yoshimura; Humihiro Nishimaki; Kazunobu Takamizawa
Journal:  Int J Implant Dent       Date:  2016-04-05

3.  Dosimetric impact of dental metallic crown on intensity-modulated radiotherapy and volumetric-modulated arc therapy for head and neck cancer.

Authors:  Takeshi Kamomae; Yoshiyuki Itoh; Kuniyasu Okudaira; Takayoshi Nakaya; Masashi Tomida; Yoshikazu Miyake; Hiroshi Oguchi; Takehiro Shiinoki; Mariko Kawamura; Noriyuki Yamamoto; Shinji Naganawa
Journal:  J Appl Clin Med Phys       Date:  2016-01-08       Impact factor: 2.102

4.  Investigating the effect of dental implant materials with different densities on radiotherapy dose distribution using Monte-Carlo simulation and pencil beam convolution algorithm.

Authors:  Oya Akyol; Bahar Dirican; Turkay Toklu; Hakan Eren; Turan Olgar
Journal:  Dentomaxillofac Radiol       Date:  2019-02-01       Impact factor: 2.419

5.  The combined effects of irradiation and herpes simplex virus type 1 infection on an immortal gingival cell line.

Authors:  Aaro Turunen; Veijo Hukkanen; Michaela Nygårdas; Jarmo Kulmala; Stina Syrjänen
Journal:  Virol J       Date:  2014-07-08       Impact factor: 4.099

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.