Literature DB >> 16420272

A new method for the 3D measurement of postoperative swelling following orthognathic surgery.

C H Kau1, A Cronin, P Durning, A I Zhurov, A Sandham, S Richmond.   

Abstract

OBJECTIVE: To describe a new method for measuring facial swelling following orthognathic surgery using a 3D laser-scanning device.
DESIGN: Prospective clinical trial. Setting and Sample Population -- University Dental Hospital, Wales College of Medicine, Biology Life and Health Sciences. Three subjects requiring bi-maxillary orthognathic surgery were recruited for the study. EXPERIMENTAL VARIABLES: Laser-scanned images of the subjects were obtained under a reproducible and controlled environment with two Minolta Vivid 900 (Osaka, Japan) optical laser-scanning devices assembled as a stereo-pair. A set of left and right scanned images was taken for each subject and each scan took an average of 2.5 s. 3D laser scans were recorded over six time periods (T1 -- pre-surgical scan, postoperatively: T2 -- 1 day, T3 -- 1 week, T4 -- 1 month, T5 -- 3 months and T6 -- 6 months). OUTCOME MEASURE: Facial scans from different time periods were overlaid onto the baseline (T6) facial scan to determine the reduction and changes in swelling following orthognathic surgery.
RESULTS: The results showed that swelling could be accurately quantified following surgery. Furthermore, there was a significant reduction in the amount of swelling 1 month postoperatively. Furthermore, the facial morphology returned to approximately 90% of the baseline facial scan at 3 months.
CONCLUSION: The 3D laser-scanning device and the method described was a reliable and accurate measure of facial swelling following surgery.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16420272     DOI: 10.1111/j.1601-6343.2006.00341.x

Source DB:  PubMed          Journal:  Orthod Craniofac Res        ISSN: 1601-6335            Impact factor:   1.826


  19 in total

1.  Evaluation of precision and accuracy assessment of different 3-D surface imaging systems for biomedical purposes.

Authors:  Maximilian Eder; Gernot Brockmann; Alexander Zimmermann; Moschos A Papadopoulos; Katja Schwenzer-Zimmerer; Hans Florian Zeilhofer; Robert Sader; Nikolaos A Papadopulos; Laszlo Kovacs
Journal:  J Digit Imaging       Date:  2013-04       Impact factor: 4.056

2.  Multimodal registration of three-dimensional maxillodental cone beam CT and photogrammetry data over time.

Authors:  N Bolandzadeh; W Bischof; C Flores-Mir; P Boulanger
Journal:  Dentomaxillofac Radiol       Date:  2012-07-27       Impact factor: 2.419

3.  A comparison between landmark and surface shape measurements in a sample of cleft lip and palate patients after secondary alveolar bone grafting.

Authors:  Chung H Kau; Liana Medina; Jeryl D English; James Xia; Jamie Gateno; John Teichgraber
Journal:  Orthodontics (Chic.)       Date:  2011

4.  Influences of different lower cervical bone graft heights on the size of the intervertebral foramen: multiple planar dynamic measurements with laser scanning.

Authors:  Rui Yang; Mengjun Ma; Lin Huang; Jichao Ye; Yong Tang; Peng Wang; Dezhen Yin; Keng Chen; Weiping Li; Huiyong Shen
Journal:  Lasers Med Sci       Date:  2018-01-30       Impact factor: 3.161

5.  Soft tissue images from cephalograms compared with those from a 3D surface acquisition system.

Authors:  Angela K Incrapera; Chung How Kau; Jeryl D English; Kathleen McGrory; David M Sarver
Journal:  Angle Orthod       Date:  2010-01       Impact factor: 2.079

6.  Importance of the vertical incisor relationship in the prediction of the soft tissue profile after Class III bimaxillary surgery.

Authors:  Gundega Jakobsone; Arild Stenvik; Lisen Espeland
Journal:  Angle Orthod       Date:  2011-11-30       Impact factor: 2.079

7.  An exploration of adolescent facial shape changes with age via multilevel partial least squares regression.

Authors:  D J J Farnell; S Richmond; J Galloway; A I Zhurov; P Pirttiniemi; T Heikkinen; V Harila; H Matthews; P Claes
Journal:  Comput Methods Programs Biomed       Date:  2021-01-08       Impact factor: 5.428

Review 8.  3D digital stereophotogrammetry: a practical guide to facial image acquisition.

Authors:  Carrie L Heike; Kristen Upson; Erik Stuhaug; Seth M Weinberg
Journal:  Head Face Med       Date:  2010-07-28       Impact factor: 2.151

9.  Photographic protocol for image acquisition in craniofacial microsomia.

Authors:  Carrie L Heike; Laura P Stueckle; Erik T Stuhaug; Luiz A Pimenta; Amelia F Drake; Daniela Vivaldi; Kathleen C Y Sie; Craig B Birgfeld
Journal:  Head Face Med       Date:  2011-12-30       Impact factor: 2.151

10.  The Reliability of a Three-Dimensional Photo System- (3dMDface-) Based Evaluation of the Face in Cleft Lip Infants.

Authors:  Rebecca Ort; Philipp Metzler; Astrid L Kruse; Felix Matthews; Wolfgang Zemann; Klaus W Grätz; Heinz-Theo Luebbers
Journal:  Plast Surg Int       Date:  2012-08-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.