OBJECTIVES: The purpose of the SCANDSTENT study was to evaluate the use of sirolimus-eluting stents (SES) in complex coronary lesions. BACKGROUND: The use of SES improves angiographic and clinical outcomes compared with bare-metal stents (BMS) in simple coronary artery lesions, but there is limited evidence of their safety and efficacy when implanted in complex lesions. METHODS: We randomly assigned 322 patients with symptomatic complex coronary artery disease to receive eitherSES or BMS. The lesions were occluded (36%), bifurcational (34%), ostial (22%), or angulated (8%) in morphology. The primary end point was the difference in minimal lumen diameter six months after stent implantation. RESULTS: The patients were well matched in terms of demographic and angiographic baseline characteristics; 18% had diabetes. The reference vessel diameter was 2.86 mm in mean, and the lesion length 18.0 mm. At follow-up, patients who received SES had a minimal lumen diameter of 2.48 mm compared with 1.65 mm in those who received BMS (p < 0.001), a diameter stenosis of 19.3% versus 43.8% (p < 0.001), and 2.0% versus 31.9% developed restenosis (p < 0.001). The rate of major adverse cardiac events was 4.3% with SES versus 29.3% with BMS (p < 0.001), and stent thrombosis was observed in 0.6% in the SES group versus 3.1% in the BMS group (p = 0.15). CONCLUSIONS: The use of SES markedly reduced restenosis and the occurrence of major adverse cardiac events in patients with complex coronary artery lesions without increasing the risk of stent thrombosis.
RCT Entities:
OBJECTIVES: The purpose of the SCANDSTENT study was to evaluate the use of sirolimus-eluting stents (SES) in complex coronary lesions. BACKGROUND: The use of SES improves angiographic and clinical outcomes compared with bare-metal stents (BMS) in simple coronary artery lesions, but there is limited evidence of their safety and efficacy when implanted in complex lesions. METHODS: We randomly assigned 322 patients with symptomatic complex coronary artery disease to receive either SES or BMS. The lesions were occluded (36%), bifurcational (34%), ostial (22%), or angulated (8%) in morphology. The primary end point was the difference in minimal lumen diameter six months after stent implantation. RESULTS: The patients were well matched in terms of demographic and angiographic baseline characteristics; 18% had diabetes. The reference vessel diameter was 2.86 mm in mean, and the lesion length 18.0 mm. At follow-up, patients who received SES had a minimal lumen diameter of 2.48 mm compared with 1.65 mm in those who received BMS (p < 0.001), a diameter stenosis of 19.3% versus 43.8% (p < 0.001), and 2.0% versus 31.9% developed restenosis (p < 0.001). The rate of major adverse cardiac events was 4.3% with SES versus 29.3% with BMS (p < 0.001), and stent thrombosis was observed in 0.6% in the SES group versus 3.1% in the BMS group (p = 0.15). CONCLUSIONS: The use of SES markedly reduced restenosis and the occurrence of major adverse cardiac events in patients with complex coronary artery lesions without increasing the risk of stent thrombosis.
Authors: Tillmann Cyrus; Huiying Zhang; John S Allen; Todd A Williams; Grace Hu; Shelton D Caruthers; Samuel A Wickline; Gregory M Lanza Journal: Arterioscler Thromb Vasc Biol Date: 2008-02-21 Impact factor: 8.311
Authors: Vladimír Dzavík; Christopher E Buller; Gerard Devlin; Ronald G Carere; G B John Mancini; Warren J Cantor; Pawel E Buszman; James M Rankin; Carlos Vozzi; John R Ross; Sandra Forman; Bruce A Barton; A Gervasio A Lamas; Judith S Hochman Journal: Catheter Cardiovasc Interv Date: 2009-05-01 Impact factor: 2.692
Authors: Sripal Bangalore; Sunil Kumar; Mario Fusaro; Nicholas Amoroso; Ajay J Kirtane; Robert A Byrne; David O Williams; James Slater; Donald E Cutlip; Frederick Feit Journal: BMJ Date: 2012-08-10
Authors: Leif Thuesen; Lisette Okkels Jensen; Hans Henrik Tilsted; Michael Mæng; Christian Terkelsen; Per Thayssen; Jan Ravkilde; Evald Høj Christiansen; Hans Erik Bøtker; Morten Madsen; Jens F Lassen Journal: Clin Epidemiol Date: 2013-09-19 Impact factor: 4.790