Literature DB >> 16409256

A digital SLR or intra-oral camera: preference for acquisition within an image analysis system for measurement of disclosed dental plaque area within clinical trials.

R N Smith1, A Rawlinson, D L Lath, A H Brook.   

Abstract

OBJECTIVES: The aim of this investigation was to compare the accuracy and reproducibility of images acquired from two types of camera (digital SLR camera, Kodak DCS410, KJP, UK and an intra-oral camera, Schick Technologies, UK) for application within an imaging system used for the quantification of disclosed dental plaque.
METHODS: Subjects refrained from brushing their teeth for 24 h. Their teeth were then disclosed with Erythrosin FDC Red 3 and duplicate sets of images were obtained by each examiner of the upper central and lateral incisors. Images were then saved and measured for dental plaque area. These data were used to calculate reliability.
RESULTS: No statistically significant bias in the measurements of plaque area was found. The reliability results showed the method was reliable. However, the image analysis system incorporating the 35 mm SRL camera was more reliable for both operators, as demonstrated by their intra-operator results. This was also collaborated by the inter-operator results.
CONCLUSION: In this investigation the digital SLR camera combined with the image analysis system and frame permitted greater reliability of dental plaque surface area measurements than the digital intra-oral camera. This conclusion was derived both from the reliability data and from the perceived ease of use and flexibility of both camera types. When combined with the use of the custom-made frame, the images using the digital SLR camera were highly reproducible, confirming the systems application within clinical trials.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16409256     DOI: 10.1111/j.1600-0765.2005.00841.x

Source DB:  PubMed          Journal:  J Periodontal Res        ISSN: 0022-3484            Impact factor:   4.419


  6 in total

1.  Development of digital shade guides for color assessment using a digital camera with ring flashes.

Authors:  Oi-Hong Tung; Yu-Lin Lai; Yi-Ching Ho; I-Chiang Chou; Shyh-Yuan Lee
Journal:  Clin Oral Investig       Date:  2010-01-05       Impact factor: 3.573

2.  Validity of scoring caries and primary molar hypomineralization (DMH) on intraoral photographs.

Authors:  M E C Elfrink; J S J Veerkamp; I H A Aartman; H A Moll; J M Ten Cate
Journal:  Eur Arch Paediatr Dent       Date:  2009-11

3.  Clinical applications of intraoral camera to increase patient compliance - current perspectives.

Authors:  Kalyana-Chakravarthy Pentapati; Hanan Siddiq
Journal:  Clin Cosmet Investig Dent       Date:  2019-08-23

4.  DenTiUS Plaque, a Web-Based Application for the Quantification of Bacterial Plaque: Development and Usability Study.

Authors:  Nicolás Vila-Blanco; Vicente Freire; Carlos Balsa-Castro; Inmaculada Tomás; María J Carreira
Journal:  J Med Internet Res       Date:  2020-09-03       Impact factor: 5.428

5.  Detecting and monitoring dental plaque levels with digital 2D and 3D imaging techniques.

Authors:  Katja Giese-Kraft; Katja Jung; Nadine Schlueter; Kirstin Vach; Carolina Ganss
Journal:  PLoS One       Date:  2022-02-15       Impact factor: 3.240

6.  New portable system for dental plaque measurement using a digital single-lens reflex camera and image analysis: Study of reliability and validation.

Authors:  Guillermo Martin Rosa; Maria Lidia Elizondo
Journal:  J Indian Soc Periodontol       Date:  2015 May-Jun
  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.