Literature DB >> 1640754

Effect of pulsatile arterial diameter variations on blood flow estimated by Doppler ultrasound.

M Eriksen1.   

Abstract

High-resolution measurements of common carotid and femoral arterial diameters have been performed by ultrasound echo devices. When combined with pulsed Doppler measurements of cross-sectional averaged velocity in the same vessels, exact calculations of flow were made possible. The median peak-to-peak pulsatile diameter variations were 0.19 mm (2.8 per cent) in the femoral artery and 0.49 mm (6.7 per cent) in the common carotid artery. Flow values were calculated either by taking the time-averaged diameter as a constant value, or by taking into account the dynamic variations in diameter. In comparing the two values, a quantification of the magnitude of error introduced by the averaging of the diameter was made possible. An error in the range 1.5-3.8 per cent was found for the femoral artery, whereas the error in the common carotid artery was in the range 0.4-3.6 per cent despite the larger amplitude of the pulsations in this vessel.

Mesh:

Year:  1992        PMID: 1640754     DOI: 10.1007/bf02446192

Source DB:  PubMed          Journal:  Med Biol Eng Comput        ISSN: 0140-0118            Impact factor:   2.602


  6 in total

1.  The relation of pulsatile pressure to flow in arteries.

Authors:  D A McDONALD
Journal:  J Physiol       Date:  1955-03-28       Impact factor: 5.182

2.  Pulse-wave model of brachial arterial pressure modulation in aging and hypertension.

Authors:  R S Chadwick; D S Goldstein; H R Keiser
Journal:  Am J Physiol       Date:  1986-07

3.  Noninvasive measurement of arterial diameters in humans using ultrasound echoes with prefiltered waveforms.

Authors:  M Eriksen
Journal:  Med Biol Eng Comput       Date:  1987-03       Impact factor: 2.602

4.  Non-invasive assessment of the age related changes in stiffness of major branches of the human arteries.

Authors:  T Kawasaki; S Sasayama; S Yagi; T Asakawa; T Hirai
Journal:  Cardiovasc Res       Date:  1987-09       Impact factor: 10.787

5.  Sonographic demonstration of buckling of the great vessels of the neck.

Authors:  B R Subramanyam; S C Horii
Journal:  AJR Am J Roentgenol       Date:  1984-06       Impact factor: 3.959

6.  Blood flow in arteries determined transcutaneously by an ultrasonic doppler velocitymeter as compared to electromagnetic measurements on the exposed vesels.

Authors:  I Guldvog; M Kjaernes; M Thoresen; L Walløe
Journal:  Acta Physiol Scand       Date:  1980-06
  6 in total
  13 in total

Review 1.  Developments in cardiovascular ultrasound. Part 2: Arterial applications.

Authors:  P R Hoskins; P J Fish; W N McDicken; C Moran
Journal:  Med Biol Eng Comput       Date:  1998-05       Impact factor: 2.602

2.  Age-related decreases in basal limb blood flow in humans: time course, determinants and habitual exercise effects.

Authors:  F A Dinenno; D R Seals; C A DeSouza; H Tanaka
Journal:  J Physiol       Date:  2001-03-01       Impact factor: 5.182

3.  Intermittent negative pressure applied to the lower limb increases foot macrocirculatory and microcirculatory blood flow pulsatility in people with spinal cord injury.

Authors:  Øyvind Heiberg Sundby; Lars Øivind Høiseth; Ingebjørg Irgens; Iacob Mathiesen; Eivind Lundgaard; Hanne Haugland; Harald Weedon-Fekjær; Jon O Sundhagen; Gunnar Sanbæk; Jonny Hisdal
Journal:  Spinal Cord       Date:  2017-12-28       Impact factor: 2.772

4.  Exercise-induced arterial adaptations in elite judo athletes.

Authors:  Panagiotis Karagounis; Maria Maridaki; Xenofon Papaharalampous; Giorgos Prionas; Panagiotis Baltopoulos
Journal:  J Sports Sci Med       Date:  2009-09-01       Impact factor: 2.988

5.  3-D Intravascular Characterization of Blood Flow Velocity Fields with a Forward-Viewing 2-D Array.

Authors:  Brooks D Lindsey; Bowen Jing; Saeyoung Kim; Graham C Collins; Muralidhar Padala
Journal:  Ultrasound Med Biol       Date:  2020-06-30       Impact factor: 2.998

6.  Simultaneous assessment of red blood cell aggregation and oxygen saturation under pulsatile flow using high-frequency photoacoustics.

Authors:  Tae-Hoon Bok; Eno Hysi; Michael C Kolios
Journal:  Biomed Opt Express       Date:  2016-06-23       Impact factor: 3.732

7.  3D noncontrast MR angiography of the distal lower extremities using flow-sensitive dephasing (FSD)-prepared balanced SSFP.

Authors:  Zhaoyang Fan; John Sheehan; Xiaoming Bi; Xin Liu; James Carr; Debiao Li
Journal:  Magn Reson Med       Date:  2009-12       Impact factor: 4.668

8.  Accuracy of volumetric flow rate measurements: an in vitro study using modern ultrasound scanners.

Authors:  Kenneth Hoyt; Felix A Hester; Randall L Bell; Mark E Lockhart; Michelle L Robbin
Journal:  J Ultrasound Med       Date:  2009-11       Impact factor: 2.153

9.  Effect of Selective Mineralocorticoid Receptor Blockade on Flow-Mediated Dilation and Insulin Resistance in Older Adults with Metabolic Syndrome.

Authors:  Moon-Hyon Hwang; Jeung-Ki Yoo; Meredith Luttrell; Thomas H Meade; Mark English; Demetra D Christou
Journal:  Metab Syndr Relat Disord       Date:  2015-08-24       Impact factor: 1.894

10.  Middle cerebral artery blood flows by combining TCD velocities and MRA diameters: in vitro and in vivo validations.

Authors:  K A Yonan; E R Greene; J M Sharrar; A Caprihan; C Qualls; C A Roldan
Journal:  Ultrasound Med Biol       Date:  2014-09-11       Impact factor: 2.998

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.