Literature DB >> 16406537

Asymmetry of right versus left intraocular pressures over 24 hours in glaucoma patients.

Arthur J Sit1, John H K Liu, Robert N Weinreb.   

Abstract

PURPOSE: To assess the asymmetry of 24-hour intraocular pressures (IOPs) between right and left eyes of untreated open-angle glaucoma (OAG) patients, and its influence on the monocular therapeutic trial.
DESIGN: Experimental study with human patients. PARTICIPANTS: Forty-one subjects (40-78 years old) with untreated OAG.
METHODS: Subjects were housed in a sleep laboratory for 24 hours. Intraocular pressures of both eyes were measured with a pneumatonometer every 2 hours with the patient in the sitting and supine positions from 7 am to 11 pm and in the supine position only from 11 pm to 7 am. Mean, peak, and trough IOPs were compared in right versus left eyes. The strength of association between right and left IOPs was assessed using coefficients of determination (R2). Validity of the monocular therapeutic trial was assessed by examining residual values from 2 linear regression models of right versus left IOP. MAIN OUTCOME MEASURES: Strength of association between IOPs of right and left eyes, and residual values from linear models of IOP.
RESULTS: No statistically significant difference was found between mean, peak, or trough IOPs of right and left eyes over a 24-hour period. The strength of association for mean IOP was only moderate (R(2) = 0.421-0.623). Residual values of > or =3 mmHg were found in 14.0%+/-12.0% (mean +/- standard deviation) of IOP measurements for a symmetric linear regression model, and 8.5%+/-10.6% of IOP measurements for a best-fit linear regression model over 24 hours.
CONCLUSIONS: In this group of untreated glaucoma patients, the strength of association between the right and left eye mean IOPs is only moderate. Residual values of > or =3 mmHg were more common using a symmetric model than with a best-fit model. The current method of performing monocular therapeutic trials in glaucoma patients is unreliable, but it may be possible to improve reliability by using several IOP measurements obtained at different times of the day instead of a single office measurement.

Entities:  

Mesh:

Year:  2006        PMID: 16406537     DOI: 10.1016/j.ophtha.2005.10.003

Source DB:  PubMed          Journal:  Ophthalmology        ISSN: 0161-6420            Impact factor:   12.079


  18 in total

1.  Comparison of efficacy of four prostaglandin analogues by bilateral treatment in healthy subjects.

Authors:  Ichiro Kawaguchi; Tomomi Higashide; Shinji Ohkubo; Chiaki Kawaguchi; Kazuhisa Sugiyama
Journal:  Jpn J Ophthalmol       Date:  2012-06-07       Impact factor: 2.447

2.  Diurnal intraocular pressure changes in eyes affected with acute primary angle closure and fellow eyes after laser peripheral iridotomy.

Authors:  Han Seok Park; Joon Mo Kim; Seong Hee Shim; Hyun Tae Kim; Jeong Hun Bae; Chul Young Choi; Ki Ho Park
Journal:  Jpn J Ophthalmol       Date:  2015-08-04       Impact factor: 2.447

3.  Comparison of 90-s versus 5-min intraoperative 5-fluorouracil in trabeculectomy.

Authors:  Andrea Zarkovic; Kent Chow; Justin S Mora
Journal:  Int Ophthalmol       Date:  2009-01-10       Impact factor: 2.031

4.  The utility of the monocular trial: data from the ocular hypertension treatment study.

Authors:  Anjali M Bhorade; Bradley S Wilson; Mae O Gordon; Paul Palmberg; Robert N Weinreb; Eydie Miller; Robert T Chang; Michael A Kass
Journal:  Ophthalmology       Date:  2010-08-12       Impact factor: 12.079

5.  24-h intraocular pressure patterns measured by Icare PRO rebound in habitual position of open-angle glaucoma eyes.

Authors:  Zhaobin Fang; Xiaolei Wang; Siyu Qiu; Xinghuai Sun; Yuhong Chen; Ming Xiao
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-04-29       Impact factor: 3.117

6.  Concordance of 24-h intraocular pressure curve in patients with untreated unilateral primary open-angle glaucoma.

Authors:  Zhongjing Lin; Shouyue Huang; Ping Huang; Changwei Li; Zhenghua Chen; Yisheng Zhong
Journal:  Exp Ther Med       Date:  2018-06-15       Impact factor: 2.447

7.  Diurnal intraocular pressure patterns are not repeatable in the short term in healthy individuals.

Authors:  Tony Realini; Robert N Weinreb; Stephen R Wisniewski
Journal:  Ophthalmology       Date:  2010-06-16       Impact factor: 12.079

8.  Variability of intraocular pressure measurements in observation participants in the ocular hypertension treatment study.

Authors:  Anjali M Bhorade; Mae O Gordon; Brad Wilson; Robert N Weinreb; Robert N Weinrab; Michael A Kass
Journal:  Ophthalmology       Date:  2009-02-25       Impact factor: 12.079

9.  Comparing the efficacy of the monocular trial treatment paradigm with multiple measurements of intraocular pressure before and after treatment initiation in primary open-angle glaucoma.

Authors:  Rohit Krishna; Peter W Debry; Corey W Waldman; Peter Koulen
Journal:  Clin Ophthalmol       Date:  2012-03-28

10.  Intraocular Pressure: Does it Measure Up?

Authors:  M Roy Wilson; Kuldev Singh
Journal:  Open Ophthalmol J       Date:  2009-09-17
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.