Literature DB >> 16406499

Selection of a battery of rapid toxicity sensors for drinking water evaluation.

William H van der Schalie1, Ryan R James, Thomas P Gargan.   

Abstract

Comprehensive identification of chemical contaminants in Army field water supplies can be a lengthy process, but rapid analytical methods suitable for field use are limited. A complementary approach is to directly measure toxicity instead of individual chemical constituents. Ten toxicity sensors utilizing enzymes, bacteria, or vertebrate cells were tested to determine the minimum number of sensors that could rapidly identify toxicity in water samples containing one of 12 industrial chemicals. The ideal sensor would respond at a concentration just exceeding the Military Exposure Guideline (MEG) level for the chemical (an estimated threshold for adverse effects) but below the human lethal concentration. Chemical solutions were provided to testing laboratories as blind samples. No sensors responded to deionized water blanks, and only one sensor responded to a hard water blank. No single toxicity sensor responded to more than six chemicals in the desired response range, and one chemical (nicotine) was not detected by any sensor with the desired sensitivity. A combination of three sensors (Microtox, the Electric Cell Substrate Impedance Sensing (ECIS) test, and the Hepatocyte low density lipoprotein (LDL) uptake test) responded appropriately to nine of twelve chemicals. Adding a fourth sensor (neuronal microelectrode array) to the test battery allowed detection of two additional chemicals (aldicarb and methamidophos), but the neuronal microelectrode array was overly sensitive to paraquat. Evaluating sensor performance using a standard set of chemicals and a desired sensitivity range provides a basis both for selecting among available toxicity sensors and for evaluating emerging sensor technologies. Recommendations for future toxicity sensor evaluations are discussed.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16406499     DOI: 10.1016/j.bios.2005.11.019

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  4 in total

1.  Resazurin reduction assay, a useful tool for assessment of heavy metal toxicity in acidic conditions.

Authors:  Mohammadreza Zare; Mohammad Mehdi Amin; Mahnaz Nikaeen; Bijan Bina; Hamidreza Pourzamani; Ali Fatehizadeh; Ensieh Taheri
Journal:  Environ Monit Assess       Date:  2015-04-20       Impact factor: 2.513

2.  Dielectrophoretic field-flow fractionation system for detection of aquatic toxicants.

Authors:  Sittisak Pui-ock; Mathuros Ruchirawat; Peter Gascoyne
Journal:  Anal Chem       Date:  2008-09-13       Impact factor: 6.986

3.  A novel cell-based hybrid acoustic wave biosensor with impedimetric sensing capabilities.

Authors:  Fei Liu; Fang Li; Anis Nurashikin Nordin; Ioana Voiculescu
Journal:  Sensors (Basel)       Date:  2013-03-04       Impact factor: 3.576

4.  Preparation and Testing of Impedance-based Fluidic Biochips with RTgill-W1 Cells for Rapid Evaluation of Drinking Water Samples for Toxicity.

Authors:  Linda M Brennan; Mark W Widder; Michael K McAleer; Michael W Mayo; Alex P Greis; William H van der Schalie
Journal:  J Vis Exp       Date:  2016-03-07       Impact factor: 1.355

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.