Literature DB >> 16404510

A SU-8/PDMS hybrid microfluidic device with integrated optical fibers for online monitoring of lactate.

Min-Hsien Wu1, Haoyuan Cai, Xia Xu, Jill P G Urban, Zhan-Feng Cui, Zheng Cui.   

Abstract

A microfluidic device with integrated optical fibres was developed for online monitoring of lactate. The device consists of a SU-8 waveguide, microfluidic channels and grooves for the insertion of optic fibres. It was fabricated by one-step photolithography of SU-8 polymer resist. Different channel widths (50-300 microm) were tested in terms of detection sensitivity. A wide range of flow rates were applied to investigate the influence of flow rate on signal fluctuations. The separation between optical fibre sensor and microfluidic channel and the width of fluidic channel have been optimized to maximize the detection sensitivity. It was revealed that 250 microm of channel width is the optimum light path length for a compromise between detection sensitivity and interference of ambient light. The independence of detection signals on flow rates was demonstrated within the range of flow rate (0.5-5 ml/hr) tested. Compared with conventional lactate detection, the device is proved to have high accuracy, relatively low limit of detection (50 mg/L) and reasonably fast response time (100 sec). The fabrication of device is simple and low cost. The present work has provided some fundamental data for further system optimization to meet specific detection requirements.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16404510     DOI: 10.1007/s10544-005-6074-y

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  4 in total

1.  Sealing SU-8 microfluidic channels using PDMS.

Authors:  Zhiyi Zhang; Ping Zhao; Gaozhi Xiao; Benjamin R Watts; Changqing Xu
Journal:  Biomicrofluidics       Date:  2011-11-09       Impact factor: 2.800

2.  Contact printing of arrayed microstructures.

Authors:  Wei Xu; Alicia M Luikart; Christopher E Sims; Nancy L Allbritton
Journal:  Anal Bioanal Chem       Date:  2010-04-28       Impact factor: 4.142

3.  Design and microfabrication of a miniature fiber optic probe with integrated lenses and mirrors for Raman and fluorescence measurements.

Authors:  Thitaphat Ngernsutivorakul; Cynthia M Cipolla; Colleen E Dugan; Shi Jin; Michael D Morris; Robert T Kennedy; Francis W L Esmonde-White
Journal:  Anal Bioanal Chem       Date:  2016-10-20       Impact factor: 4.142

4.  Fully inkjet-printed microfluidics: a solution to low-cost rapid three-dimensional microfluidics fabrication with numerous electrical and sensing applications.

Authors:  Wenjing Su; Benjamin S Cook; Yunnan Fang; Manos M Tentzeris
Journal:  Sci Rep       Date:  2016-10-07       Impact factor: 4.379

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.