Literature DB >> 16404507

Flat-chip microanalytical enzyme sensor for salivary amylase activity.

Masaki Yamaguchi1, Mitsuo Deguchi, Junichi Wakasugi.   

Abstract

It is considered that measurement of salivary alpha-amylase activity is a useful tool for evaluating the sympathetic nervous system. The purpose of this research is to demonstrate a new design of a flat-chip microanalytical enzyme sensor (flat-chip sensor) for salivary amylase activity as a Micro-Electro-Mechanical Systems (MEMS), which may be used for wearable analytical systems. To meet this purpose, the biosensor needs to be miniaturized and to possess high-sensitivity. A pre-column and a flat-enzyme electrode were incorporated in a flow cell of volume 25.7 ml. In order to miniaturize the flow cell, two enzymatic membranes containing maltose phosphorylase obtained from Enterococcus hirae (MP membrane) and glucose oxidase and peroxidase (GOD-POD membrane) were immobilised on the same planar surface. As a result, a flat-chip sensor incorporating a flow cell as small as a C battery was produced. The optimum conditions of three parameters of the fabricated flat-chip sensor, the immobilising method of the enzymatic membrane, dropping volume of the mixed enzymatic solution and flow rate of the sample solution, were examined. An analytical system for 0-190 kU/l amylase activity with R(2) of 0.97 was fabricated with a sample volume of 50 microl. This research indicates the possibility of a wearable biosensor for continuous monitoring of salivary amylase activity.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16404507     DOI: 10.1007/s10544-005-6071-1

Source DB:  PubMed          Journal:  Biomed Microdevices        ISSN: 1387-2176            Impact factor:   2.838


  3 in total

Review 1.  Saliva-based biosensors: noninvasive monitoring tool for clinical diagnostics.

Authors:  Radha S P Malon; Sahba Sadir; Malarvili Balakrishnan; Emma P Córcoles
Journal:  Biomed Res Int       Date:  2014-09-08       Impact factor: 3.411

2.  Frontal Electroencephalogram Alpha Asymmetry during Mental Stress Related to Workplace Noise.

Authors:  Emad Alyan; Naufal M Saad; Nidal Kamel; Mohd Zuki Yusoff; Mohd Azman Zakariya; Mohammad Abdul Rahman; Christophe Guillet; Frederic Merienne
Journal:  Sensors (Basel)       Date:  2021-03-11       Impact factor: 3.576

3.  Flow-based systems for rapid and high-precision enzyme kinetics studies.

Authors:  Supaporn Kradtap Hartwell; Kate Grudpan
Journal:  J Anal Methods Chem       Date:  2012-04-22       Impact factor: 2.193

  3 in total