Literature DB >> 16399301

Should the "elephant trunk" be skeletonized? Total arch replacement combined with stented elephant trunk implantation for Stanford type A aortic dissection.

Zhi-Gang Liu1, Li-Zhong Sun, Qian Chang, Jun-Ming Zhu, Chao Dong, Chun-Tao Yu, Yong-Min Liu, Hai-Tao Zhang.   

Abstract

OBJECTIVES: To eliminate the residual false lumen in the descending thoracic aorta and improve long-term outcomes of surgical intervention for Stanford type A aortic dissection, we performed the skeletonized "elephant trunk" procedure in the ascending aorta and aortic arch replacement combined with transaortic stented graft implantation into the descending aorta for both acute and chronic type A aortic dissection, and the short-term results were compared.
METHODS: Between April 2003 and November 2004, 60 consecutive patients (mean age, 53 +/- 16.7; approximate range, 28-78 years) with acute (n = 36) or chronic (n = 24) type A aortic dissection underwent this procedure. Right axillary artery cannulation was used for cardiopulmonary bypass and selected cerebral perfusion. The stented graft, a 10-cm-long woven Dacron graft with a self-expandable stent, was implanted through the aortic arch during hypothermic circulatory arrest. Enhanced electric beam computed tomography was performed in each patient before discharge, 3 months after the operation, and once each year thereafter to evaluate the postoperative time course of the residual false lumen.
RESULTS: Cardiopulmonary bypass time was 166 +/- 38 minutes, and average selective cerebral perfusion and lower body arrest time was 30 +/- 15 minutes. The in-hospital mortality was 3.3% (2/60). Thrombus obliteration of the residual false lumen in the descending thoracic aorta was observed in 92% and 85% of the acute and chronic aortic dissections, respectively, 3 months postoperatively. There was no late death during follow-up.
CONCLUSIONS: The skeletonized elephant trunk procedure is an effective way of closing the residual false lumen of the descending aorta and might contribute to better long-term outcomes for both acute and chronic type A aortic dissection.

Entities:  

Mesh:

Year:  2005        PMID: 16399301     DOI: 10.1016/j.jtcvs.2005.09.015

Source DB:  PubMed          Journal:  J Thorac Cardiovasc Surg        ISSN: 0022-5223            Impact factor:   5.209


  31 in total

Review 1.  Sun's procedure for chronic type A aortic dissection: total arch replacement using a tetrafurcate graft with stented elephant trunk implantation.

Authors:  Li-Zhong Sun; Wei-Guo Ma; Jun-Ming Zhu; Jun Zheng; Yong-Min Liu; Bulat A Ziganshin; John A Elefteriades
Journal:  Ann Cardiothorac Surg       Date:  2013-09

2.  Management of the difficult left subclavian artery during aortic arch repair.

Authors:  Ali Hage; Olivia Ginty; Adam Power; Luc Dubois; Francois Dagenais; Jehangir J Appoo; John Bozinovski; Michael W A Chu
Journal:  Ann Cardiothorac Surg       Date:  2018-05

3.  Endovascular repair of residual intimal tear or distal new entry after frozen elephant trunk for type A aortic dissection.

Authors:  Xu-Dong Pan; Bin Li; Wei-Guo Ma; Jun Zheng; Yong-Min Liu; Jun-Ming Zhu; Lian-Jun Huang; Li-Zhong Sun
Journal:  J Thorac Dis       Date:  2017-03       Impact factor: 2.895

4.  Analysis of risk factors for and the prognosis of postoperative acute respiratory distress syndrome in patients with Stanford type A aortic dissection.

Authors:  Mei-Fang Chen; Liang-Wan Chen; Hua Cao; Yong Lin
Journal:  J Thorac Dis       Date:  2016-10       Impact factor: 2.895

Review 5.  Open Stented Grafts for Frozen Elephant Trunk Technique: Technical Aspects and Current Outcomes.

Authors:  Wei-Guo Ma; Jun Zheng; Li-Zhong Sun; John A Elefteriades
Journal:  Aorta (Stamford)       Date:  2015-08-01

Review 6.  Sun's procedure for complex aortic arch repair: total arch replacement using a tetrafurcate graft with stented elephant trunk implantation.

Authors:  Wei-Guo Ma; Jun-Ming Zhu; Jun Zheng; Yong-Min Liu; Bulat A Ziganshin; John A Elefteriades; Li-Zhong Sun
Journal:  Ann Cardiothorac Surg       Date:  2013-09

7.  Sun's procedure of total arch replacement using a tetrafurcated graft with stented elephant trunk implantation: analysis of early outcome in 398 patients with acute type A aortic dissection.

Authors:  Wei-Guo Ma; Jun Zheng; Song-Bo Dong; Wei Lu; Kai Sun; Rui-Dong Qi; Yong-Min Liu; Jun-Ming Zhu; Qian Chang; Li-Zhong Sun
Journal:  Ann Cardiothorac Surg       Date:  2013-09

8.  Dr. Sun's Procedure for Type A Aortic Dissection: Total Arch Replacement Using Tetrafurcate Graft With Stented Elephant Trunk Implantation.

Authors:  Wei-Guo Ma; Jun Zheng; Yong-Min Liu; Jun-Ming Zhu; Li-Zhong Sun
Journal:  Aorta (Stamford)       Date:  2013-06-01

9.  Renal protective effect of the aortic balloon occlusion technique in total arch replacement with frozen elephant trunk.

Authors:  Bowen Zhang; Yanxiang Liu; Hongwei Guo; Yunfeng Li; Yi Shi; Shenghua Liang; Hong Liu; Xiaogang Sun
Journal:  Ann Cardiothorac Surg       Date:  2020-05

10.  Impact of body mass index on early and mid-term outcomes after surgery for acute Stanford type A aortic dissection.

Authors:  Yanxiang Liu; Bowen Zhang; Shenghua Liang; Yaojun Dun; Luchen Wang; Haoyu Gao; Jie Ren; Hongwei Guo; Xiaogang Sun
Journal:  J Cardiothorac Surg       Date:  2021-06-22       Impact factor: 1.637

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.