Literature DB >> 16399029

Use of an optical flow method for the analysis of serial CT lung images.

Lawrence Dougherty1, Drew A Torigian, John D Affusso, Jane C Asmuth, Warren B Gefter.   

Abstract

RATIONALE AND
OBJECTIVES: Serial CT lung studies are difficult to compare due to misregistration between image sets. An optical flow method (OFM) was adapted for use on CT lung images to register images and visualize changes between studies. Three applications were investigated: lung nodule assessment; evaluation of pulmonary enhancement; and functional changes due to air trapping.
MATERIALS AND METHODS: From an initial clinical study, a follow-up study was created by digitally manipulating the images to simulate patient positioning errors and nodule growth. Nodule growth was measured from the temporal subtraction of registered images. In application to the assessment of pulmonary enhancement, pre and postcontrast images from a patient with acute pulmonary embolism (PE) were registered. A map of the perfused blood volume was computed from the ratio of aligned lung volumes. Functional changes in the lung were demonstrated using images from a patient with air trapping. End-inspiratory and end-expiratory volumes were aligned and displacement fields estimated using the OFM. Principal strains were computed from the displacement fields.
RESULTS: All image volumes were aligned with at least 0.95 correlation. OFM estimates of displacement showed excellent agreement with the prescribed displacements with 0.33 pixel RMS error. Nodule growth was evident in the presence of significant positioning errors. In the PE case, enhancement ratios indicated a hypoperfused area consistent with an occlusive hypodense filling defect. For the air trapping case, a strain map showed functional changes along the interface of the air trap.
CONCLUSIONS: The OFM can facilitate the detection and quantification of changes between serial CT lung studies.

Entities:  

Mesh:

Year:  2006        PMID: 16399029     DOI: 10.1016/j.acra.2005.09.081

Source DB:  PubMed          Journal:  Acad Radiol        ISSN: 1076-6332            Impact factor:   3.173


  5 in total

Review 1.  Using imaging as a biomarker for asthma.

Authors:  Abhaya Trivedi; Chase Hall; Eric A Hoffman; Jason C Woods; David S Gierada; Mario Castro
Journal:  J Allergy Clin Immunol       Date:  2017-01       Impact factor: 10.793

Review 2.  Recent Advances in Computed Tomography Imaging in Chronic Obstructive Pulmonary Disease.

Authors:  Sandeep Bodduluri; Joseph M Reinhardt; Eric A Hoffman; John D Newell; Surya P Bhatt
Journal:  Ann Am Thorac Soc       Date:  2018-03

3.  Assessment of regional lung function with multivolume (1)H MR imaging in health and obstructive lung disease: comparison with (3)He MR imaging.

Authors:  Francesca Pennati; James D Quirk; Dmitriy A Yablonskiy; Mario Castro; Andrea Aliverti; Jason C Woods
Journal:  Radiology       Date:  2014-06-15       Impact factor: 11.105

4.  Deformation analysis of 3D tagged cardiac images using an optical flow method.

Authors:  Chun Xu; James J Pilla; Gamaliel Isaac; Joseph H Gorman; Aaron S Blom; Robert C Gorman; Zhou Ling; Lawrence Dougherty
Journal:  J Cardiovasc Magn Reson       Date:  2010-03-30       Impact factor: 5.364

5.  Evaluation of Deformable Image Registration for Three-Dimensional Temporal Subtraction of Chest Computed Tomography Images.

Authors:  Ping Yan; Yoshie Kodera; Kazuhiro Shimamoto
Journal:  Int J Biomed Imaging       Date:  2017-10-12
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.