Literature DB >> 16395808

Microchip capillary electrophoresis with amperometric detection for rapid separation and detection of seleno amino acids.

Joseph Wang1, Saverio Mannino, Carmen Camera, Madhu Prakash Chatrathi, Matteo Scampicchio, Jiri Zima.   

Abstract

This article describes an effective microchip capillary-electrophoresis protocol for rapid and effective measurements of food-related seleno amino acids, including Se-methionine (Se-Met), Se-ethionine (Se-Eth), Se-methyl cysteine (Se-Cys), utilizing o-phtaldialdeyde/2-mercaptoethanol (OPA/2-ME) derivatization. Relevant parameters of the chip separation and amperometric detection are examined and optimized using a response surface methodology (RSM). Under optimum conditions, the analytes could be separated and detected in a 30 mM borate buffer (pH 9.3, with 28 mM sodium dodecul sulfate) within 300 s using a separation voltage of 2000V and a detection voltage of +0.9 V. Linear calibration plots are observed for micromolar concentrations of the Se-amino acid compounds. The negligible sample volumes used in the microchip procedure obviates surface fouling common to amperometric measurements of selenoamino-acid compounds. The new microchip protocol offers great promise for a wide range of food applications requiring fast measurements and negligible sample consumption.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16395808     DOI: 10.1016/j.chroma.2005.07.055

Source DB:  PubMed          Journal:  J Chromatogr A        ISSN: 0021-9673            Impact factor:   4.759


  5 in total

Review 1.  Bioanalytical profile of the L-arginine/nitric oxide pathway and its evaluation by capillary electrophoresis.

Authors:  Dmitri Y Boudko
Journal:  J Chromatogr B Analyt Technol Biomed Life Sci       Date:  2007-02-15       Impact factor: 3.205

Review 2.  Isotachophoresis: Theory and Microfluidic Applications.

Authors:  Ashwin Ramachandran; Juan G Santiago
Journal:  Chem Rev       Date:  2022-06-22       Impact factor: 72.087

3.  Sensitive, selective analysis of selenium oxoanions using microchip electrophoresis with contact conductivity detection.

Authors:  Scott D Noblitt; Lucian C Staicu; Christopher J Ackerson; Charles S Henry
Journal:  Anal Chem       Date:  2014-07-29       Impact factor: 6.986

4.  MCE-electrochemical detection for following interactions of ssDNA and dsDNA with methylene blue.

Authors:  Mario Castaño-Alvarez; Ana Fernández-la-Villa; María Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Electrophoresis       Date:  2009-06       Impact factor: 3.535

5.  Electroactive intercalators for DNA analysis on microchip electrophoresis.

Authors:  Mario Castaño-Alvarez; M Teresa Fernández-Abedul; Agustín Costa-García
Journal:  Electrophoresis       Date:  2007-12       Impact factor: 3.535

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.