Literature DB >> 16394948

Preliminary results: Effect of whole-body cooling in patients with myasthenia gravis.

Christine M Mermier1, Suzanne M Schneider, Alfred B Gurney, Heidi M Weingart, M Virginia Wilmerding.   

Abstract

INTRODUCTION: Local muscle cooling has been shown to reduce symptoms in some neuromuscular diseases.
PURPOSE: To determine whether lowering body temperature using a cooling vest would result in improvement in muscle strength, subjective perceptions of weakness and fatigue, and pulmonary function in patients with generalized myasthenia gravis (MG).
METHODS: Patients (five female, one male) with generalized MG, aged 29-58 yr, were studied when mean body temperature was lowered (34.9 +/- 0.62 degrees C) using a cooling vest (CT) and at normal body temperature (35.8 +/- 0.58 degrees C) (NT). Isokinetic and isometric muscle strength and isokinetic endurance were measured using upper body muscle groups. The myasthenic muscle score (MMS) was performed to assess muscle impairment specific to MG patients. Pulmonary function measurements included forced vital capacity (FVC), maximal inspiratory pressure (MIP), and maximal expiratory pressure (MEP). The fatigue impact scale (FIS) was used to track subjective perceptions of fatigue. Core body and skin temperatures were measured throughout each NT and CT trial.
RESULTS: Mean body temperature (0.65(core) + 0.35(skin)) was reduced significantly following 30-45 min of cooling (NT = 35.76 +/- 0.58, CT = 34.96 +/- 0.62 degrees C). The MMS and MIP increased significantly (NT = 91.9 vs CT = 96.3; and NT = 69.3 vs CT = 79.5 cm/H2O) with cooling. Although all other variables were not statistically different between temperature conditions, individual results for grip strength of the right hand, fatigue ratio for wrist extensors and shoulder internal and external rotators, FVC, and MEP showed improvement for the majority of the subjects.
CONCLUSION: Cooling in patients with MG shows promise to decrease symptoms of weakness and fatigue, thus allowing increased muscle strength and endurance in some patients.

Entities:  

Mesh:

Year:  2006        PMID: 16394948     DOI: 10.1249/01.mss.0000180887.33650.0f

Source DB:  PubMed          Journal:  Med Sci Sports Exerc        ISSN: 0195-9131            Impact factor:   5.411


  3 in total

1.  Design and performance of personal cooling garments based on three-layer laminates.

Authors:  M Rothmaier; M Weder; A Meyer-Heim; J Kesselring
Journal:  Med Biol Eng Comput       Date:  2008-06-25       Impact factor: 2.602

2.  Evaluating the temperature effects of ice and heat tests on ptosis due to Myasthenia Gravis.

Authors:  Emmanuel Marinos; Katherine Buzzard; Clare L Fraser; Stephen Reddel
Journal:  Eye (Lond)       Date:  2018-05-10       Impact factor: 3.775

3.  The Systematic Bias of Ingestible Core Temperature Sensors Requires a Correction by Linear Regression.

Authors:  Andrew P Hunt; Aaron J E Bach; David N Borg; Joseph T Costello; Ian B Stewart
Journal:  Front Physiol       Date:  2017-04-27       Impact factor: 4.566

  3 in total