Optimization of measurement conditions of an energy dispersive X-ray fluorescence spectrometer with high-energy polarized beam excitation for analysis of aerosol filters.

Z Spolnik1, K Belikov, K Van Meel, E Adriaenssens, F De Roeck, R Van Grieken.   

Abstract

A new commercial energy dispersive X-ray fluorescence spectrometer (EDXRF), applying a three-dimensional geometry and high-energy excitation, was optimized for the quantitative analysis of aerosols deposited on filters. The preliminary results are presented here. First-order calibration curves were obtained for 20 elements deposited on the filters. The accuracy of the applied method and of the obtained calibration curves was checked by the measurement of a standard reference material from NIST. The precision of the analysis for the majority of the analytes was better than 10%. Due to the obtained low detection limits, it is possible to determine the analytes usually present at very low concentrations in ambient air, such as, e.g., Cd, Sb, Cr, and V. It is also possible to decrease significantly the time of analysis or the time of the sampling.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16390584     DOI: 10.1366/000370205775142647

Source DB:  PubMed          Journal:  Appl Spectrosc        ISSN: 0003-7028            Impact factor:   2.388


  3 in total

1.  Effects of a constructional intervention on airborne and deposited particulate matter in the Portuguese National Tile Museum, Lisbon.

Authors:  Willemien Anaf; Benjamin Horemans; Teresa I Madeira; M Luisa Carvalho; Karolien De Wael; René Van Grieken
Journal:  Environ Sci Pollut Res Int       Date:  2012-07-25       Impact factor: 4.223

2.  Health implications of atmospheric aerosols from asbestos-bearing road pavements traditionally used in Southern Brazil.

Authors:  Ricardo H M Godoi; Sérgio J Gonçalves; Célia Sayama; Gabriela Polezer; José M Reis Neto; Bálint Alföldy; René Van Grieken; Carlos A Riedi; Carlos I Yamamoto; Ana F L Godoi; László Bencs
Journal:  Environ Sci Pollut Res Int       Date:  2016-09-28       Impact factor: 4.223

3.  Effect of operating and sampling conditions on the exhaust gas composition of small-scale power generators.

Authors:  Marianne Smits; Floris Vanpachtenbeke; Benjamin Horemans; Karolien De Wael; Birger Hauchecorne; Herman Van Langenhove; Kristof Demeestere; Silvia Lenaerts
Journal:  PLoS One       Date:  2012-03-19       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.