Literature DB >> 16390236

A comparison of glass and plastic blood collection tubes for routine and specialized coagulation assays: a comprehensive study.

Alexander Kratz1, Nancy Stanganelli, Elizabeth M Van Cott.   

Abstract

CONTEXT: Blood collection tubes made from plastic are beginning to replace glass tubes. Coagulation test results can be influenced easily by preanalytic factors, including exposure to surfaces that activate the clotting cascade.
OBJECTIVE: To compare the effects of the blood collection tube material on 22 coagulation assays performed in clinical laboratories.
DESIGN: Paired blood samples from 28 healthy volunteers were drawn into BD Vacutainer Glass Citrate Tubes and BD Vacutainer Plus Plastic Citrate Tubes, and the results of coagulation assays were determined in parallel.
RESULTS: No statistically significant differences were observed between glass and plastic for 14 assays: prothrombin time (and international normalized ratio); activated partial thromboplastin time; activated protein C resistance; antithrombin activity; factors II, V, VIII, and IX; alpha2-antiplasmin; plasminogen activity; von Willebrand factor antigen; ristocetin cofactor; thrombin time; and reptilase time. Statistically significant differences were found for fibrinogen; chromogenic protein C activity; protein S activity; PTT-LA lupus anticoagulant-sensitive activated partial thromboplastin time; and factors VII, X, XI, and XII. Mean differences ranged from 0.4% to 5.5% and were unlikely to be of clinical significance.
CONCLUSIONS: The results of this study suggest that plastic tubes can be used in place of glass tubes for a wide variety of coagulation assays.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16390236     DOI: 10.5858/2006-130-39-ACOGAP

Source DB:  PubMed          Journal:  Arch Pathol Lab Med        ISSN: 0003-9985            Impact factor:   5.534


  6 in total

1.  Guidance on the critical shortage of sodium citrate coagulation tubes for hemostasis testing.

Authors:  Robert C Gosselin; Annette Bowyer; Emmanuel J Favaloro; Jill M Johnsen; Giuseppe Lippi; Richard A Marlar; Keith Neeves; Marian A Rollins-Raval
Journal:  J Thromb Haemost       Date:  2021-09-02       Impact factor: 16.036

2.  Influence of blood collection systems on coagulation tests.

Authors:  Soner Yavaş; Selime Ayaz; S Kenan Köse; Fatma Ulus; A Tulga Ulus
Journal:  Turk J Haematol       Date:  2012-12-05       Impact factor: 1.831

Review 3.  Interferences from blood collection tube components on clinical chemistry assays.

Authors:  Raffick A R Bowen; Alan T Remaley
Journal:  Biochem Med (Zagreb)       Date:  2014-02-15       Impact factor: 2.313

4.  Impact of the phlebotomy training based on CLSI/NCCLS H03-a6 - procedures for the collection of diagnostic blood specimens by venipuncture.

Authors:  Gabriel Lima-Oliveira; Giuseppe Lippi; Gian Luca Salvagno; Martina Montagnana; Geraldo Picheth; Gian Cesare Guidi
Journal:  Biochem Med (Zagreb)       Date:  2012       Impact factor: 2.313

5.  An on-site preparable, novel bone-grafting complex consisting of human platelet-rich fibrin and porous particles made of a recombinant collagen-like protein.

Authors:  Tsuneyuki Tsukioka; Takahiro Hiratsuka; Masayuki Nakamura; Taisuke Watanabe; Yutaka Kitamura; Kazushige Isobe; Toshimitsu Okudera; Hajime Okudera; Akihiko Azuma; Kohya Uematsu; Koh Nakata; Tomoyuki Kawase
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2018-10-01       Impact factor: 3.368

6.  Flexible UHF RFID Tag for Blood Tubes Monitoring.

Authors:  Mohamed El Khamlichi; Alejandro Alvarez Melcon; Otman El Mrabet; Mohammed Ali Ennasar; Juan Hinojosa
Journal:  Sensors (Basel)       Date:  2019-11-09       Impact factor: 3.576

  6 in total