Literature DB >> 16387174

Effect of continuous application of shear stress on liver tissue: continuous application of appropriate shear stress has advantage in protection of liver tissue.

T Torii1, M Miyazawa, I Koyama.   

Abstract

Rapid blood flow changes occur in the liver following a massive resection or in the grafted liver following transplantation, under which shear stress (SS) change induced by the flow change may determine the postoperative results. We observed changes in liver tissue structure and liver-specific function, and consequently assessed SS effect. The cultured liver tissue exposed to continuous application of moderate SS was shown to express and maintain a long-term liver-specific function. There was also evidence showing that destruction of the liver structure was inhibited. However, the cultured liver tissue not exposed to SS or exposed to high SS was shown to lose liver-specific function soon after expression. The liver structure was destroyed in the early stage of incubation. These results suggested that continuous application of appropriate SS has advantages over other types of stresses to protect liver tissue.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16387174     DOI: 10.1016/j.transproceed.2005.10.118

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  5 in total

Review 1.  Clinical implications of cellular stress responses.

Authors:  Borut Poljšak; Irina Milisav
Journal:  Bosn J Basic Med Sci       Date:  2012-05       Impact factor: 3.363

2.  A whole-organ regenerative medicine approach for liver replacement.

Authors:  Alejandro Soto-Gutierrez; Li Zhang; Chris Medberry; Ken Fukumitsu; Denver Faulk; Hongbin Jiang; Janet Reing; Roberto Gramignoli; Junji Komori; Mark Ross; Masaki Nagaya; Eric Lagasse; Donna Stolz; Stephen C Strom; Ira J Fox; Stephen F Badylak
Journal:  Tissue Eng Part C Methods       Date:  2011-04-20       Impact factor: 3.056

Review 3.  The impact of microfluidics in high-throughput drug-screening applications.

Authors:  Paola De Stefano; Elena Bianchi; Gabriele Dubini
Journal:  Biomicrofluidics       Date:  2022-05-26       Impact factor: 3.258

4.  On being the right size: scaling effects in designing a human-on-a-chip.

Authors:  Christopher Moraes; Joseph M Labuz; Brendan M Leung; Mayumi Inoue; Tae-Hwa Chun; Shuichi Takayama
Journal:  Integr Biol (Camb)       Date:  2013-09       Impact factor: 2.192

Review 5.  Adaptive response, evidence of cross-resistance and its potential clinical use.

Authors:  Irina Milisav; Borut Poljsak; Dušan Šuput
Journal:  Int J Mol Sci       Date:  2012-08-29       Impact factor: 6.208

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.