Literature DB >> 16386974

Role of silicon contamination on calcification of hydrophilic acrylic intraocular lenses.

Liliana Werner1, Brian Hunter, Scott Stevens, Jesse J L Chew, Nick Mamalis.   

Abstract

PURPOSE: To verify the presence of the element silicon on hydrophilic acrylic intraocular lenses (IOLs) explanted because of calcification.
DESIGN: Interventional case series with clinicopathological correlation.
METHODS: Twenty explanted IOLs with surface deposits (MemoryLens), and 20 with deposits mostly within their optic substance (SC60B-OUV and Aqua-Sense; 10 each) were used. After gross, microscopic, and histochemical analyses to confirm the presence of deposits, the lenses underwent scanning electron microscopy (SEM) with energy dispersive x-ray spectroscopy (EDS) for elemental composition, on the external surface of MemoryLens IOLs, and on the surface and internal substance of SC60B-OUV and Aqua-Sense IOLs. The weight percentage of the element silicon was obtained at the level of deposits, and at adjacent deposit-free areas in all lenses.
RESULTS: Scanning electron microscopy (SEM) coupled with EDS confirmed that the composition of the deposits was calcium/phosphate in all cases. The element silicon was found in all 40 lenses, on all areas analyzed. The silicon weight percentage was higher at the level of the deposits. The presence of aluminum on five MemoryLens IOLs, and in most of the SC60B-OUV and Aqua-Sense lenses might be related to scattering from the aluminum mounting stubs used for surface analyses.
CONCLUSIONS: Silicone compounds have been implicated in the calcification of another hydrophilic acrylic design (Hydroview). They may also have a role in the calcification of other hydrophilic acrylic IOLs. Further investigation on the relationship between the presence of the element silicon and the silicone compounds found on calcified hydrophilic acrylic lenses is necessary.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16386974     DOI: 10.1016/j.ajo.2005.08.045

Source DB:  PubMed          Journal:  Am J Ophthalmol        ISSN: 0002-9394            Impact factor:   5.258


  10 in total

1.  Severe prelenticular membrane formation on the surface of a hydrophilic acrylic intraocular lens after cataract surgery in an eye with an Ahmed valve implant.

Authors:  Yong-Sun Ahn; Jin A Choi
Journal:  Int J Ophthalmol       Date:  2015-04-18       Impact factor: 1.779

2.  [In Process Citation].

Authors:  M Fuest; D Kuerten; P Walter; S Ruetten; N Plange
Journal:  Ophthalmologe       Date:  2015-12       Impact factor: 1.059

3.  Intraocular lens opacification mimicking the appearance of a congenital lamellar cataract.

Authors:  C Patel; S Hamada; Y Athanasiadis; R Bates; G M Saleh
Journal:  Eye (Lond)       Date:  2012-08-31       Impact factor: 3.775

4.  Perioperative complications and clinical outcomes of intraocular lens exchange in patients with opacified lenses.

Authors:  Roberto Fernández-Buenaga; Jorge L Alió; Laura Pinilla-Cortés; Rafael I Barraquer
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2013-07-03       Impact factor: 3.117

5.  [Opacification of a hydrophilic intraocular lens 4 years after cataract surgery. A biomaterial analysis].

Authors:  R Khoramnia; J P Salgado; G U Auffarth; S Schmidt; A Wegner; K A Kobuch; C Winkler von Mohrenfels
Journal:  Ophthalmologe       Date:  2012-05       Impact factor: 1.059

6.  Opacification of the optic of an Akreos Adapt intraocular lens.

Authors:  Chong Eun Lee; Yu Cheol Kim; Sung Dong Chang
Journal:  Korean J Ophthalmol       Date:  2010-11-23

Review 7.  Recent Advances of Intraocular Lens Materials and Surface Modification in Cataract Surgery.

Authors:  Chenqi Luo; Hanle Wang; Xinyi Chen; Jingjie Xu; Houfa Yin; Ke Yao
Journal:  Front Bioeng Biotechnol       Date:  2022-06-08

8.  Optical and material analysis of opacified hydrophilic intraocular lenses after explantation: a laboratory study.

Authors:  Tamer Tandogan; Ramin Khoramnia; Chul Young Choi; Alexander Scheuerle; Martin Wenzel; Philipp Hugger; Gerd U Auffarth
Journal:  BMC Ophthalmol       Date:  2015-11-25       Impact factor: 2.209

9.  Akreos Adapt AO Intraocular Lens Opacification: A Case Report.

Authors:  Matteo Forlini; Giancarlo Dell'aversana Orabona; Adriana Ionela Bratu; Paolo Rossini; Gian Maria Cavallini; Cesare Forlini
Journal:  Case Rep Ophthalmol       Date:  2013-09-26

10.  Glistening formation in a new hydrophobic acrylic intraocular lens.

Authors:  Timur M Yildirim; Hui Fang; Sonja K Schickhardt; Qiang Wang; Patrick R Merz; Gerd U Auffarth
Journal:  BMC Ophthalmol       Date:  2020-05-06       Impact factor: 2.209

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.