Literature DB >> 16386676

Flow-dependent changes in Doppler-derived aortic valve effective orifice area are real and not due to artifact.

Lyes Kadem1, Régis Rieu, Jean G Dumesnil, Louis-Gilles Durand, Philippe Pibarot.   

Abstract

OBJECTIVES: We sought to determine whether the flow-dependent changes in Doppler-derived valve effective orifice area (EOA) are real or due to artifact.
BACKGROUND: It has frequently been reported that the EOA may vary with transvalvular flow in patients with aortic stenosis. However, the explanation of the flow dependence of EOA remains controversial and some studies have suggested that the EOA estimated by Doppler-echocardiography (EOA(Dop)) may underestimate the actual EOA at low flow rates.
METHODS: One bioprosthetic valve and three rigid orifices were tested in a mock flow circulation model over a wide range of flow rates. The EOA(Dop) was compared with reference values obtained using particle image velocimetry (EOA(PIV)).
RESULTS: There was excellent agreement between EOA(Dop) and EOA(PIV) (r2 = 0.94). For rigid orifices of 0.5 and 1.0 cm2, no significant change in the EOA was observed with increasing flow rate. However, substantial increases of both EOA(Dop) and EOA(PIV) were observed when stroke volume increased from 20 to 70 ml both in the 1.5 cm2 rigid orifice (+52% for EOA(Dop) and +54% for EOA(PIV)) and the bioprosthetic valve (+62% for EOA(Dop) and +63% for EOA(PIV)); such changes are explained either by the presence of unsteady effects at low flow rates and/or by an increase in valve leaflet opening.
CONCLUSIONS: The flow-dependent changes in EOA(Dop) are not artifacts but represent real changes in EOA attributable either to unsteady effects at low flow rates and/or to changes in valve leaflet opening. Such changes in EOA(Dop) can be relied on for clinical judgment making.

Entities:  

Mesh:

Year:  2005        PMID: 16386676     DOI: 10.1016/j.jacc.2005.05.100

Source DB:  PubMed          Journal:  J Am Coll Cardiol        ISSN: 0735-1097            Impact factor:   24.094


  9 in total

Review 1.  Low-gradient aortic valve stenosis: value and limitations of dobutamine stress testing.

Authors:  J Bermejo; R Yotti
Journal:  Heart       Date:  2006-04-18       Impact factor: 5.994

2.  Assessing aortic valve area in aortic stenosis by continuity equation: a novel approach using real-time three-dimensional echocardiography.

Authors:  Kian Keong Poh; Robert A Levine; Jorge Solis; Liang Shen; Mary Flaherty; Yue-Jian Kang; J Luis Guerrero; Judy Hung
Journal:  Eur Heart J       Date:  2008-02-09       Impact factor: 29.983

3.  Evaluation of aortic stenosis severity using 4D flow jet shear layer detection for the measurement of valve effective orifice area.

Authors:  Julio Garcia; Michael Markl; Susanne Schnell; Bradley Allen; Pegah Entezari; Riti Mahadevia; S Chris Malaisrie; Philippe Pibarot; James Carr; Alex J Barker
Journal:  Magn Reson Imaging       Date:  2014-04-24       Impact factor: 2.546

Review 4.  Echocardiographic Evaluation of Aortic Stenosis - Normal Flow and Low Flow Scenarios.

Authors:  Ian G Burwash
Journal:  Eur Cardiol       Date:  2014-12

5.  Cardiovascular magnetic resonance evaluation of aortic stenosis severity using single plane measurement of effective orifice area.

Authors:  Julio Garcia; Oscar R Marrufo; Alfredo O Rodriguez; Eric Larose; Philippe Pibarot; Lyes Kadem
Journal:  J Cardiovasc Magn Reson       Date:  2012-04-06       Impact factor: 5.364

6.  Discrepancies between cardiovascular magnetic resonance and Doppler echocardiography in the measurement of transvalvular gradient in aortic stenosis: the effect of flow vorticity.

Authors:  Julio Garcia; Romain Capoulade; Florent Le Ven; Emmanuel Gaillard; Lyes Kadem; Philippe Pibarot; Éric Larose
Journal:  J Cardiovasc Magn Reson       Date:  2013-09-20       Impact factor: 5.364

7.  Transcatheter aortic valves produce unphysiological flows which may contribute to thromboembolic events: An in-vitro study.

Authors:  Andrea Ducci; Francesco Pirisi; Spyridon Tzamtzis; Gaetano Burriesci
Journal:  J Biomech       Date:  2016-11-03       Impact factor: 2.712

Review 8.  Cell Sources for Tissue Engineering Strategies to Treat Calcific Valve Disease.

Authors:  Eva Jover; Marco Fagnano; Gianni Angelini; Paolo Madeddu
Journal:  Front Cardiovasc Med       Date:  2018-11-06

Review 9.  Multimodality Imaging for Discordant Low-Gradient Aortic Stenosis: Assessing the Valve and the Myocardium.

Authors:  Ezequiel Guzzetti; Mohamed-Salah Annabi; Philippe Pibarot; Marie-Annick Clavel
Journal:  Front Cardiovasc Med       Date:  2020-12-03
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.