| Literature DB >> 16386473 |
Katrien Lanckmans1, Ralph Clinckers, Ann Van Eeckhaut, Sophie Sarre, Ilse Smolders, Yvette Michotte.
Abstract
A microbore LC-MS/MS method is developed and validated for the quantification of the anti-epileptic drug oxcarbazepine (OXC) and its active metabolite 10,11-dihydro-10-hydroxycarbamazepine (MHD) in rat brain microdialysates, together with the internal standard for microdialysis probe calibration, 2-methyl-5H-dibenz(b,f)azepine-5-carboxamide (m-CBZ). The benefits of gradient versus isocratic separation are shown, next to the improved sensitivity resulting from the addition of 0.1% formic acid to the mobile phase. The coupling of microdialysis with ESI-MS requires sample desalting for which column switching was applied. Using weighed regression to calculate the calibration curves (1-1000 ng/mL), the assay was validated in terms of linearity, accuracy and precision, yielding a sensitive (limit of quantification is 1 ng/mL) and selective method for quantification of OXC, MHD and m-CBZ. By applying this method, we were able to determine the extracellular concentrations of OXC and MHD during at least 4h after intraperitoneal (i.p.) administration of 10 mg/kg OXC.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16386473 DOI: 10.1016/j.jchromb.2005.12.003
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205