Literature DB >> 16382481

Effective detection of peptides containing cysteine sulfonic acid using matrix-assisted laser desorption/ionization and laser desorption/ionization on porous silicon mass spectrometry.

Tomoya Kinumi1, Yukiyasu Shimomae, Ryuichi Arakawa, Yoshiro Tatsu, Yasushi Shigeri, Noboru Yumoto, Etsuo Niki.   

Abstract

Cysteine sulfonic acid-containing peptides, being typical acidic peptides, exhibit low response in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. In this study, matrix conditions and the effect of diammonium hydrogencitrate (DAHC) as additive were investigated for ionization of cysteine sulfonic acid-containing peptides in MALDI. A matrix-free ionization method, desorption/ionization on porous silicon (DIOS), was also utilized to evaluate the effect of DAHC. When equimolar three-component mixtures of peptides carrying free cysteine, cysteine sulfonic acid, and carbamidomethyl cysteine were measured by MALDI using a common matrix, alpha-cyano-4-hydroxycinnamic acid (CHCA), no signal corresponding to cysteine sulfonic acid-containing peptide could be observed in the mass spectrum. However, by addition of DAHC to CHCA, the peaks of cysteine sulfonic acid-containing peptides were successfully observed, as well as when using 2,4,6-trihydroxyacetophenone (THAP) and 2,6-dihydroxyacetophenone with DAHC. In the DIOS mass spectra of these analytes, the use of DAHC also enhanced the peak intensity of the cysteine sulfonic acid-containing peptides. On the basis of studies with these model peptides, tryptic digests of oxidized peroxiredoxin 6 were examined as a complex peptide mixture by MALDI and DIOS. In MALDI, the peaks of cysteine sulfonic acid-containing peptides were observed when using THAP/DAHC as the matrix, but this was not so with CHCA. In DIOS, the signal from cysteine sulfonic acid-containing peptides was suppressed; however, the use of DAHC significantly enhanced the signal intensity with an increase in the number of observed peptides and increased signal-to-noise ratio in the DIOS spectra. The results show that DAHC in the matrix or on the DIOS chip decreases discrimination and suppression effects in addition to suppressing alkali-adduct ions, which leads to a beneficial effect on protonation of peptides containing cysteine sulfonic acid.

Entities:  

Mesh:

Substances:

Year:  2006        PMID: 16382481     DOI: 10.1002/jms.973

Source DB:  PubMed          Journal:  J Mass Spectrom        ISSN: 1076-5174            Impact factor:   1.982


  4 in total

Review 1.  Cardiovascular redox and ox stress proteomics.

Authors:  Vikas Kumar; Timothy Dean Calamaras; Dagmar Haeussler; Wilson Steven Colucci; Richard Alan Cohen; Mark Errol McComb; David Pimentel; Markus Michael Bachschmid
Journal:  Antioxid Redox Signal       Date:  2012-08-10       Impact factor: 8.401

2.  Targeted Annotation of S-Sulfonylated Peptides by Selective Infrared Multiphoton Dissociation Mass Spectrometry.

Authors:  Nicholas B Borotto; Phillip J McClory; Brent R Martin; Kristina Håkansson
Journal:  Anal Chem       Date:  2017-08-01       Impact factor: 6.986

Review 3.  Cysteine oxidative posttranslational modifications: emerging regulation in the cardiovascular system.

Authors:  Heaseung S Chung; Sheng-Bing Wang; Vidya Venkatraman; Christopher I Murray; Jennifer E Van Eyk
Journal:  Circ Res       Date:  2013-01-18       Impact factor: 17.367

4.  Chasing cysteine oxidative modifications: proteomic tools for characterizing cysteine redox status.

Authors:  Christopher I Murray; Jennifer E Van Eyk
Journal:  Circ Cardiovasc Genet       Date:  2012-10-01
  4 in total