Literature DB >> 16381715

The refined shielding design for the cyclotron room of the Buddhist Tzu Chi General Hospital.

R D Sheu1, C C Chen, R J Sheu, C H Kao, S H Jiang.   

Abstract

Full-scale Monte Carlo simulations of the cyclotron room of the Buddhist Tzu Chi General Hospital were carried out to improve the inadequate maze design. The double differential neutron source from the 18O(p,n)18F reaction was adopted for the calculation. The weight window variance reduction technique, where the weight window was set by applying the adjoint flux, has been implemented in the MCNP run to facilitate the calculation of the dose rates outside the cyclotron room. Dose rates including neutron and gamma-ray components were calculated for some maze shielding modifications.

Mesh:

Year:  2005        PMID: 16381715     DOI: 10.1093/rpd/nci194

Source DB:  PubMed          Journal:  Radiat Prot Dosimetry        ISSN: 0144-8420            Impact factor:   0.972


  1 in total

1.  Comparison of neutron fluxes in an 18-MeV unshielded cyclotron room and a 16.5-MeV self-shielded cyclotron room.

Authors:  Toshioh Fujibuchi; Genki Horitsugi; Ichiro Yamaguchi; Akihisa Eto; Yasuo Iwamoto; Satoshi Obara; Takashi Iimori; Yoshitada Masuda; Hiroshi Watanabe; Jun Hatazawa
Journal:  Radiol Phys Technol       Date:  2012-03-24