AIM: To evaluate the feasibility of detecting duct-dependent congenital heart disease before hospital discharge by using pulse oximetry. DESIGN: Case-control study. SETTING: A supra-regional referral centre for paediatric cardiac surgery in Sweden. PATIENTS: 200 normal term newborns with echocardiographically normal hearts (median age 1.0 d) and 66 infants with critical congenital heart disease (CCHD; median age 3 d). METHODS: Pulse oximetry was performed in the right hand and one foot using a new-generation pulse oximeter (NGoxi) and a conventional-technology oximeter (CToxi). RESULTS: With the NGoxi, normal newborns showed a median postductal saturation of 99% (range 94-100%); intra-observer variability showed a mean difference of 0% (SD 1.3%), and inter-observer variability was 0% (SD 1.5%). The CToxi recorded a significantly greater proportion of postductal values below 95% (41% vs 1%) in the normal newborns compared with NGoxi (p<0.0001). The CCHD group showed a median postductal saturation of 90% (45-99%) with the NGoxi. Analysis of distributions suggested a screening cut-off of <95%; however, this still gave 7/66 false-negative patients, all with aortic arch obstruction. Best sensitivity was obtained by adding one further criterion: saturation of <95% in both hand and foot or a difference of >+/-3% between hand and foot. These combined criteria gave a sensitivity of 98.5%, specificity of 96.0%, positive predictive value of 89.0% and negative predictive value of 99.5%. CONCLUSION: Systematic screening for CCHD with high accuracy requires a new-generation oximeter, and comparison of saturation values from the right hand and one foot substantially improves the detection of CCHD.
AIM: To evaluate the feasibility of detecting duct-dependent congenital heart disease before hospital discharge by using pulse oximetry. DESIGN: Case-control study. SETTING: A supra-regional referral centre for paediatric cardiac surgery in Sweden. PATIENTS: 200 normal term newborns with echocardiographically normal hearts (median age 1.0 d) and 66 infants with critical congenital heart disease (CCHD; median age 3 d). METHODS: Pulse oximetry was performed in the right hand and one foot using a new-generation pulse oximeter (NGoxi) and a conventional-technology oximeter (CToxi). RESULTS: With the NGoxi, normal newborns showed a median postductal saturation of 99% (range 94-100%); intra-observer variability showed a mean difference of 0% (SD 1.3%), and inter-observer variability was 0% (SD 1.5%). The CToxi recorded a significantly greater proportion of postductal values below 95% (41% vs 1%) in the normal newborns compared with NGoxi (p<0.0001). The CCHD group showed a median postductal saturation of 90% (45-99%) with the NGoxi. Analysis of distributions suggested a screening cut-off of <95%; however, this still gave 7/66 false-negative patients, all with aortic arch obstruction. Best sensitivity was obtained by adding one further criterion: saturation of <95% in both hand and foot or a difference of >+/-3% between hand and foot. These combined criteria gave a sensitivity of 98.5%, specificity of 96.0%, positive predictive value of 89.0% and negative predictive value of 99.5%. CONCLUSION: Systematic screening for CCHD with high accuracy requires a new-generation oximeter, and comparison of saturation values from the right hand and one foot substantially improves the detection of CCHD.
Authors: Shakila Thangaratinam; Jane Daniels; Andrew K Ewer; Javier Zamora; Khalid S Khan Journal: Arch Dis Child Fetal Neonatal Ed Date: 2007-03-07 Impact factor: 5.747
Authors: Matthew E Oster; Susan W Aucott; Jill Glidewell; Jesse Hackell; Lazaros Kochilas; Gerard R Martin; Julia Phillippi; Nelangi M Pinto; Annamarie Saarinen; Marci Sontag; Alex R Kemper Journal: Pediatrics Date: 2016-04-15 Impact factor: 7.124
Authors: P Nuntnarumit; P Thanomsingh; A Limrungsikul; S Wanitkun; T Sirisopikun; P Ausayapao Journal: J Perinatol Date: 2017-10-19 Impact factor: 2.521
Authors: Frank Thomas Riede; Cornelia Wörner; Ingo Dähnert; Andreas Möckel; Martin Kostelka; Peter Schneider Journal: Eur J Pediatr Date: 2010-03-01 Impact factor: 3.183