| Literature DB >> 16380301 |
Kiyotaka Usui1, Takanori Hishinuma, Hiroaki Yamaguchi, Naoki Tachiiri, Junichi Goto.
Abstract
Rapid and reliable methods for identification of chlorhexidine (CHD) and nonylphenolethoxylates (NPEOn) in antiseptic and hemolyzed blood using electrospray ionization mass spectrometry (ESI-MS) were developed. Fragmental analysis provides accurate evidence for the presence of CHD in the samples. For the determination of CHD in hemolyzed blood, the method was also developed using LC-ESI-MS. Linearity of calibration curve was obtained over the concentration range of 0.1-11 microg/mL with residuals from -4.3 to 6.7%. We applied the methods to the case of suicidal injection of antiseptic and successfully detected CHD and NPEOn from hemolyzed blood. The CHD concentration was 352 microg/mL.Entities:
Mesh:
Substances:
Year: 2005 PMID: 16380301 DOI: 10.1016/j.jchromb.2005.11.051
Source DB: PubMed Journal: J Chromatogr B Analyt Technol Biomed Life Sci ISSN: 1570-0232 Impact factor: 3.205