Literature DB >> 16379621

Experimental measurements of particle deposition in three proximal lung bifurcation models with an idealized mouth-throat.

Y Zhang1, Warren H Finlay.   

Abstract

In this paper, particle deposition in three idealized proximal lung bifurcation models with an idealized mouth-throat were investigated experimentally. These bifurcation models included (1) a small symmetric bifurcation, (2) an intermediate asymmetric bifurcation, and (3) a large symmetric bifurcation. An idealized mouth-throat geometry (the "Alberta geometry") was used as the inlet to these bifurcation models. Monodisperse aerosol particles of DEHS (di-2-ethylhexyl-sebecate) oil with mass median diameters in the range of 2.5-7.5 microm were employed at steady flow rates of 30-90 L/min. Particle deposition measurements were conducted by gravimetry. The results show that particle deposition in the mouth-throat and trachea accounts for the major portion of total deposition in the entire models used, and particle deposition fraction in the proximal lung bifurcations is lower compared with that deposited in the regions upstream (the mouth-throat and the trachea). Total particle deposition efficiency increases with increasing either inertial parameter or Stokes number. Total particle deposition varies appreciably from model to model. The laryngeal jet is the key factor dominating particle deposition within the trachea. An effect of Reynolds number on particle deposition efficiency in the trachea is observed. In addition, particle deposition in the bifurcation region is influenced little by the upstream flow condition, and therefore the effect of the laryngeal jet on deposition seemingly does not propagate to the bifurcations downstream.

Entities:  

Mesh:

Substances:

Year:  2005        PMID: 16379621     DOI: 10.1089/jam.2005.18.460

Source DB:  PubMed          Journal:  J Aerosol Med        ISSN: 0894-2684


  8 in total

1.  On intra- and intersubject variabilities of airflow in the human lungs.

Authors:  Jiwoong Choi; Merryn H Tawhai; Eric A Hoffman; Ching-Long Lin
Journal:  Phys Fluids (1994)       Date:  2009-10-13       Impact factor: 3.521

2.  Convective flow dominates aerosol delivery to the lung segments.

Authors:  C Darquenne; C van Ertbruggen; G K Prisk
Journal:  J Appl Physiol (1985)       Date:  2011-04-07

3.  Good Cascade Impactor Practice (GCIP) and considerations for "in-use" specifications.

Authors:  S C Nichols; J P Mitchell; C M Shelton; D L Roberts
Journal:  AAPS PharmSciTech       Date:  2013-01-24       Impact factor: 3.246

4.  Regional deposition of particles in an image-based airway model: large-eddy simulation and left-right lung ventilation asymmetry.

Authors:  Andrew R Lambert; Patrick O'Shaughnessy; Merryn H Tawhai; Eric A Hoffman; Ching-Long Lin
Journal:  Aerosol Sci Technol       Date:  2011-01       Impact factor: 2.908

5.  Lower Inspiratory Breathing Depth Enhances Pulmonary Delivery Efficiency of ProAir Sprays.

Authors:  Mohamed Talaat; Xiuhua April Si; Jinxiang Xi
Journal:  Pharmaceuticals (Basel)       Date:  2022-06-03

6.  Method for Fabricating Transparent Patient-Specific Vocal Tract Replicas.

Authors:  Michael Rollins; Liran Oren
Journal:  Cleft Palate Craniofac J       Date:  2021-11-10

7.  Developing ways to evaluate in the laboratory how inhalation devices will be used by patients and care-givers: the need for clinically appropriate testing.

Authors:  Jolyon P Mitchell; Jason A Suggett
Journal:  AAPS PharmSciTech       Date:  2014-06-04       Impact factor: 3.246

8.  Multivariate Analysis of Effects of Asthmatic Patient Respiratory Profiles on the In Vitro Performance of a Reservoir Multidose and a Capsule-Based Dry Powder Inhaler.

Authors:  Francesca Buttini; Irene Pasquali; Gaetano Brambilla; Diego Copelli; Massimiliano Dagli Alberi; Anna Giulia Balducci; Ruggero Bettini; Viviana Sisti
Journal:  Pharm Res       Date:  2015-11-16       Impact factor: 4.200

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.