Literature DB >> 16378212

Digital area measurement of fundus landmarks.

Siamak Ansari-Shahrezaei1, Erdem Ergun, Michael Stur.   

Abstract

PURPOSE: To present and validate an image analysis technique for the calculation of the true projection area of fundus landmarks from a digital fundus image. The authors present the description, technical details and results of the study.
METHODS: Experimental study using a calibrated Gullstrand-type model eye with a scale of half circles in the centre of the artificial fundus. The axial length of the model eye was set to different values ranging from 21 mm to 29 mm, and the area of a half circle was calculated from digital fundus images with a magnification-calibrated image analysis program (UTHSCSA Image Tool). The calibration was based on Littmann's formula for correcting the magnification of fundus images.
RESULTS: The maximum deviation of the calculated area size from the true fundus object area was -3.7% under myopic and +3.4% under hyperopic conditions. The 95% confidence interval for repeated area measurements was from +1.83 to -1.46%.
CONCLUSIONS: The magnification-calibrated image analysis technique based on Littmann's formula is a non-invasive, accurate and reproducible tool for true area measurement of fundus landmarks.

Mesh:

Year:  2005        PMID: 16378212     DOI: 10.1007/s00417-005-0189-y

Source DB:  PubMed          Journal:  Graefes Arch Clin Exp Ophthalmol        ISSN: 0721-832X            Impact factor:   3.117


  10 in total

1.  Construction of a model eye and its applications.

Authors:  A R Rudnicka; D F Edgar; A G Bennett
Journal:  Ophthalmic Physiol Opt       Date:  1992-10       Impact factor: 3.117

2.  Constructing retinal fundus photomontages. A new computer-based method.

Authors:  A A Mahurkar; M A Vivino; B L Trus; E M Kuehl; M B Datiles; M I Kaiser-Kupfer
Journal:  Invest Ophthalmol Vis Sci       Date:  1996-07       Impact factor: 4.799

3.  Absolute ocular fundus dimensions measured by multiple-beam interference fringes.

Authors:  P Baumbach; B Rassow; W Wesemann
Journal:  Invest Ophthalmol Vis Sci       Date:  1989-11       Impact factor: 4.799

4.  [Determining the true size of an object on the fundus of the living eye].

Authors:  H Littmann
Journal:  Klin Monbl Augenheilkd       Date:  1988-01       Impact factor: 0.700

5.  [A model of Gullstrand's "normal eye"].

Authors:  B Rassow
Journal:  Ophthalmologica       Date:  1972       Impact factor: 3.250

6.  Possible errors in the measurement of retinal lesions.

Authors:  J V Arnold; J W Gates; K M Taylor
Journal:  Invest Ophthalmol Vis Sci       Date:  1993-07       Impact factor: 4.799

7.  Improvements on Littmann's method of determining the size of retinal features by fundus photography.

Authors:  A G Bennett; A R Rudnicka; D F Edgar
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1994-06       Impact factor: 3.117

8.  Interference fringe scale for absolute ocular fundus measurement.

Authors:  S J Kennedy; B Schwartz; T Takamoto; J K Eu
Journal:  Invest Ophthalmol Vis Sci       Date:  1983-02       Impact factor: 4.799

9.  [Determination of the real size of an object on the fundus of the living eye].

Authors:  H Littmann
Journal:  Klin Monbl Augenheilkd       Date:  1982-04       Impact factor: 0.700

10.  Size of the optic nerve scleral canal and comparison with intravital determination of optic disc dimensions.

Authors:  J B Jonas; G C Gusek; I Guggenmoos-Holzmann; G O Naumann
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  1988       Impact factor: 3.117

  10 in total
  2 in total

1.  Magnification-corrected photodynamic therapy.

Authors:  Siamak Ansari-Shahrezaei; Erdem Ergun; Robert Chong; Adnan Tufail; Andreas Wedrich; Michael Stur
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2006-10-06       Impact factor: 3.117

2.  The effect of laser unit on photodynamic therapy spot size.

Authors:  Siamak Ansari-Shahrezaei; Susanne Binder; Michael Stur
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2010-07-27       Impact factor: 3.117

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.