Chest radiography and the evaluation of the neonate for congenital heart disease.

B Fonseca1, R-K Chang, M Senac, G Knight, M S Sklansky.   

Abstract

We assessed the utility of the chest film as a screening tool for term and preterm neonates with suspected structural heart disease. Three independent observers, blinded to patient diagnosis, retrospectively evaluated the initial chest film for each of 128 consecutive neonates with suspected heart disease (gestational age, 23-42 weeks; birth weight, 500-4,621 g) who had undergone both chest radiography and echocardiography. These evaluations were subsequently compared with the results of the respective echocardiograms, read by board-certified pediatric cardiologists blinded to the chest film and chest film interpretation. Kappa statistics demonstrated moderate correlation (0.42-0.48) among different observers in their interpretation of the chest films but poor correlation (0.15-0.34) between chest radiography and echocardiography. The chest film had a low sensitivity for structural heart disease (26-59%), with a negative predictive value of 46-52%. Among neonates less than 2 kg or younger than 35 weeks of gestation, the chest film had still lower sensitivity for detecting heart disease. Despite agreement among observers in chest film interpretation, the chest film does not function as a screening test for neonates with suspected heart disease, particularly in small or premature neonates. In neonates with suspected heart disease, echocardiography should be considered, even in patients with chest films that do not suggest congenital heart disease.

Entities:  

Mesh:

Year:  2005        PMID: 16374686     DOI: 10.1007/s00246-005-8649-z

Source DB:  PubMed          Journal:  Pediatr Cardiol        ISSN: 0172-0643            Impact factor:   1.655


  15 in total

1.  Detection of transposition of the great arteries in fetuses reduces neonatal morbidity and mortality.

Authors:  D Bonnet; A Coltri; G Butera; L Fermont; J Le Bidois; J Kachaner; D Sidi
Journal:  Circulation       Date:  1999-02-23       Impact factor: 29.690

2.  Evaluation of a diagnostic algorithm for heart disease in neonates.

Authors:  R C Franklin; D J Spiegelhalter; F J Macartney; K Bull
Journal:  BMJ       Date:  1991-04-20

3.  Improved surgical outcome after fetal diagnosis of hypoplastic left heart syndrome.

Authors:  W Tworetzky; D B McElhinney; V M Reddy; M M Brook; F L Hanley; N H Silverman
Journal:  Circulation       Date:  2001-03-06       Impact factor: 29.690

4.  A roentgenologic-electrocardiographic approach to cyanotic forms of heart disease.

Authors:  L P Elliott; G L Schiebler
Journal:  Pediatr Clin North Am       Date:  1971-11       Impact factor: 3.278

5.  Noninvasive tests in the initial evaluation of heart murmurs in children.

Authors:  J W Newburger; A Rosenthal; R G Williams; K Fellows; O S Miettinen
Journal:  N Engl J Med       Date:  1983-01-13       Impact factor: 91.245

6.  Heart size on chest x-ray as a predictor of cardiac enlargement by echocardiography in children.

Authors:  G M Satou; R V Lacro; T Chung; K Gauvreau; K J Jenkins
Journal:  Pediatr Cardiol       Date:  2001 May-Jun       Impact factor: 1.655

7.  Effectiveness of pulse oximetry screening for congenital heart disease in asymptomatic newborns.

Authors:  Robert I Koppel; Charlotte M Druschel; Tonia Carter; Barry E Goldberg; Prabhu N Mehta; Rohit Talwar; Fredrick Z Bierman
Journal:  Pediatrics       Date:  2003-03       Impact factor: 7.124

8.  Precision and accuracy of clinical and radiological signs in premature infants at risk of patent ductus arteriosus.

Authors:  P Davis; S Turner-Gomes; K Cunningham; C Way; R Roberts; B Schmidt
Journal:  Arch Pediatr Adolesc Med       Date:  1995-10

9.  The value of the routine chest roentgenogram in the cardiological evaluation of infants and children. A prospective study.

Authors:  A M Temmerman; E L Mooyaart; P P Taverne
Journal:  Eur J Pediatr       Date:  1991-07       Impact factor: 3.183

10.  Chest roentgenogram in the evaluation of heart defects in asymptomatic infants and children with a cardiac murmur: reproducibility and accuracy.

Authors:  N H Birkebaek; L K Hansen; B Elle; P E Andersen; M Friis; M Egeblad; K Damgaard-Pedersen; N T Nielsen; H Oxhøj
Journal:  Pediatrics       Date:  1999-02       Impact factor: 7.124

View more
  2 in total

Review 1.  Neonatal cardiac imaging.

Authors:  Rajesh Krishnamurthy
Journal:  Pediatr Radiol       Date:  2010-04

2.  Intraobserver and interobserver agreement of the interpretation of pediatric chest radiographs.

Authors:  Jeremiah Johnson; Jeffrey A Kline
Journal:  Emerg Radiol       Date:  2010-01-21
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.