BACKGROUND: Given the limited evidence to support the technical aspects of screw placement for treatment of femoral neck fractures, we conducted an observational study to evaluate demographic and radiographic variables associated with fixation failure.
METHODS: Eligible patients with femoral neck fractures were treated with multiple cannulated screws across three academic centers during a 6-year period. The following variables were evaluated for their predictive value for fixation failure: age, gender, fracture type, presence of comminution, total number of screws, the absence of a washer, the screw configuration, reduction quality, the distance of the most inferior screw to the inferior neck, and screw alignment. Variables were evaluated separately and in a multivariable regression model.
RESULTS: Eighty patients were included in the study. The overall failure rate was 30%. We identified four variables associated with fixation failure. These included the lack of washers (odds ratio [OR], 11.2; p = 0.03), imperfect quality of reduction (OR, 9.7; p < 0.01), age greater than 75 years (OR, 5.1; p = 0.04), and displaced versus undisplaced fracture type (OR, 3.8; p < 0.01). These four variables accounted for 43% of the variability in fixation failure (R(2) = 0.43). All other variables including the distance of the most inferior screw to the inferior/medial neck were found to be not significant.
CONCLUSION: This study confirms previous findings in the literature that increased age, a displaced fracture type, and poor reduction increase the risk of fixation failure. Contradictory to current belief, there was no significant association between the distance of the inferior screw to the inferior/medial femoral neck cortex and fixation failure. A novel finding of the present study is that the use of washers significantly decreases the risk of fixation failure.

Entities:  

Mesh:

Year:  2005        PMID: 16374290     DOI: 10.1097/01.ta.0000188130.99626.8c

Source DB:  PubMed          Journal:  J Trauma        ISSN: 0022-5282


  7 in total

Review 1.  Surgical treatment options in patients with impaired bone quality.

Authors:  Norman A Johanson; Jody Litrenta; Jay M Zampini; Frederic Kleinbart; Haviva M Goldman
Journal:  Clin Orthop Relat Res       Date:  2011-08       Impact factor: 4.176

Review 2.  Fractured neck of femur--internal fixation versus arthroplasty.

Authors:  Ernst Sendtner; Tobias Renkawitz; Peter Kramny; Michael Wenzl; Joachim Grifka
Journal:  Dtsch Arztebl Int       Date:  2010-06-11       Impact factor: 5.594

3.  Patient and Surgical Factors Affecting Fusion Rates After Arthroscopic and Open Ankle Fusion: A Review of a High-Risk Cohort.

Authors:  Ashish B Shah; William Davis; Zachary L Littlefield; Sean Young; Bradley Alexander; Nicholas A Andrews; Ankit Khurana; Benjamin Cage; Tanvee Sinha; Gerald McGwin; Ashish Shah
Journal:  Indian J Orthop       Date:  2022-04-25       Impact factor: 1.033

4.  Stability of L-shaped and inverted triangle fixation assemblies in treating Pauwels type II femoral neck fracture: a comparative mechanical study.

Authors:  Vincenzo Giordano; Roger Pletsch Paes; Danilo Diniz Alves; Arthur Bonfim Amaral; William D Belangero; Marcos Giordano; Anderson Freitas; Hilton A Koch
Journal:  Eur J Orthop Surg Traumatol       Date:  2018-04-24

5.  Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients.

Authors:  Atin Jaiswal; Yashwant S Tanwar; Masood Habib
Journal:  Indian J Orthop       Date:  2013-09       Impact factor: 1.251

6.  Four quadrant parallel peripheral screw fixation for displaced femoral neck fractures in elderly patients.

Authors:  Sachin Upadhyay; Haroon Khizir Taqi Raza
Journal:  Indian J Orthop       Date:  2014-03       Impact factor: 1.251

7.  Author's reply.

Authors:  Bhava Rj Satish; Atmakuri V Ranganadham; Karruppasamy Ramalingam; Sujit Kumar Tripathy
Journal:  Indian J Orthop       Date:  2014-03       Impact factor: 1.251

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.